Factory-Installed Options
wc_tx000880gb.fm
62
4.5
Temperature-Activated Shutters
The shutters
(a)
are mounted to the top of the generator enclosure.
The shutters are designed to keep the engine compartment warm, thus increasing
engine temperature during cold weather operation. The shutters are activated
through a wax-pellet actuator
(b)
that is connected to the generator's cooling
system. As radiator coolant warms, the wax-pellet actuator engages a linkage
(c)
that opens the shutters. As the coolant cools, the shutters close.
4.6
Lockable Battery Disconnect
A lockable ON/OFF switch is available which disconnects the battery. A padlock
(not included) securely locks the switch in the OFF position. If equipped, the battery
disconnect switch is mounted to the upper skid beneath the access door on either
the right or left side of the machine.
NOTICE:
Do not use the battery disconnect switch while the engine is running.
Damage to electrical components may occur.
Содержание G 150
Страница 1: ...Mobile Generator G 150 G 180 G 240 OPERATOR S MANUAL 0171953en 003 0709 0 1 7 1 9 5 3 E N ...
Страница 2: ......
Страница 4: ...Foreword G 150 180 240 wc_tx000869gb fm 4 ...
Страница 12: ...Safety Information G 150 180 240 wc_si000265gb fm 12 wc_si000265gb fm 12 1 6 Label Locations ...
Страница 13: ...G 150 180 240 Safety Information wc_si000265gb fm 13 wc_gr005517 G H J R GG FF R A H K ...
Страница 22: ...Operation G 150 180 240 wc_tx000867gb fm 22 2 2 Control Panel wc_gr005090 m n u d e a t b f h c g j o l k ...
Страница 63: ...Factory Installed Options wc_tx000880gb fm 63 Notes ...
Страница 64: ...Schematics G 150 180 240 wc_tx000879gb fm 64 5 Schematics 5 1 DC Schematic G 150 G 180 G 240 wc_gr005459 ...