![Wacker Neuson EH 25 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/wacker-neuson/eh-25/eh-25_operators-manual_3315723045.webp)
14 Technical data
45
Example
You utilize an EH 25/230
and want to use an extension cable with a length of
30 m.
The machine has an input voltage of 230 V.
According to the table, the extension cable must feature a cross-section area of
2,5 mm
2
.
Machines
Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]
EH 65/120
120 1~
–
16
< 95
14
< 149
12
< 235
10
Machines
Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]
EH 75/240
240 1~
< 21
1,5
< 35
2,5
< 56
4
< 83
6
Machines
Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]
EH 75/240
240 1~
– 16
< 96
14
< 152
12
< 240
10