10 Troubleshooting
100_0202_ts_0010.fm
57
13
Machine overloaded
Machine is overloaded, because the soil
density is too high.
Deactivate the machine and
then re-activate it.
To prevent overload, observe the following rules:
Avoid operation on soils that are too hard to compact.
Reduce the compaction performance by actuating the slow / fast
rocker switch.
Switch-over from fast to slow operation.
14
Overload sensor
shutdown
Overload sensor or electrical connection
is defective.
Have the machine repaired.*
15
Address comparison
of IR transfer
No fault. Transmission channel is
synchronized between remote control
and machine.
16
Incorrect transmitter
unit for IR transfer
Incorrect model of remote control.
Use correct model of remote
control.
17
Incorrect address for
IR transfer
Transmission channel on the remote
control has been incorrectly set.
Synchronize the
transmission channel
between the machine and
remote control.
18
Allow the machine to
cool down...
Coolant level is too low.
Top up coolant.
Engine is overheated.
Allow engine to cool down.
Cooling fins of the cooler are dirty.
Blow cooling fins with
compressed air from the
inside to the outside from a
safe distance.
Cooling system is leaking.
Have the machine repaired.*
Temperature sensor or electrical
connection is defective.
19
Excess temperature
of the machine
Coolant level is too low.
Top up coolant.
Engine is overheated.
Allow engine to cool down.
Cooling fins of the cooler are dirty.
Blow cooling fins with
compressed air from the
inside to the outside from a
safe distance.
Cooling system is leaking.
Have the machine repaired.*
Temperature sensor or electrical
connection is defective.
20
Temperature sensor
error
Temperature sensor or electrical
connection is defective.
At very low external temperatures, the
coolant does not reach the required
temperature of 55°C during the warm-up
phase. The machine will cancel the
warm-up phase but is ready for
operation.
21
Automatic start error
Fuel tank is empty.
Top up fuel.
Defect in fuel system.
Engine, diesel valve, or electrical
connection of the diesel valve is
defective.
Have the machine repaired.*
Error code