![Wacker Neuson DPU Series Скачать руководство пользователя страница 38](http://html2.mh-extra.com/html/wacker-neuson/dpu-series/dpu-series_operators-manual_3241581038.webp)
8 Operation and use
100_0202_op_0011.fm
38
1. Open rear protective hood.
2. Press the ON/OFF switch on the machine in order to deactivate it. If the operation and receiving unit
control lamps turn off, the machine is deactivated.
3. Charge rechargeable battery of the remote control with the charger cable.
4. Close rear protective hood.
Decommissioning machine in an emergency situation (emergency stop)
1. Pressing the emergency shutdown switch – the machine will immediately stop moving and vibration
and will automatically deactivate itself.
To unlock, turn the emergency shutdown switch to the left. The machine can then be re-activated.
Item
Designation
Item
Designation
1
Control lamps
3
ON/OFF switch (red)
2
Display
NOTE
If the machine is not deactivated, it will automatically deactivate after approx. 1 hour
(factory default setting).
The turn-off time can be set in the configuration menu.
NOTE
The emergency shutdown switch is a safety device and should only be used for the
immediate shutdown of the machine in the case of an emergency situation.
Item
Designation
1
Emergency shutdown switch
1
2
3
1