wc_tx000642gb.fm
41
CRT 48
Maintenance
5.13
Servicing the Air Cleaner
1. Unlock clamps
(a)
and remove cover
(b)
.
2. Remove cartridge
(c)
from air cleaner body.
The filter can be cleaned by blowing compressed air breadthways outside and
inside the cartridge, at a pressure not greater than 4.9 bar (70 psi), or by knocking
the front of the filter several times against a flat surface. Replace filter if it appears
heavily soiled or damaged.
3. Carefully clean out air cleaner cover.
4. Install filter in body.
5. Install cover and lock clamps.
NOTICE:
NEVER
run engine without air cleaner. Severe engine damage will occur.
WARNING
NEVER
use gasoline or other types of low flash point solvents for cleaning the air
cleaner. A fire or explosion could result.