CRT 48-31V-ES
Maintenance
wc_tx000144gb.fm
37
Machine does not respond
correctly to control lever
movement.
Sheared key.
Check all keys in drive
system.
Loose electrical connector on
actuator or joystick.
Check all connections.
Electronic control board
failure.
Replace electronic control
board.
Trowel noisy.
Trowel blades have become
misaligned and are contacting
each other during rotation.
Replace damaged blades.
Align blades so that one set
represents a (+) and the other
an (x) when viewed from
above.
Sheared key.
Check all keys in drive
system.
Loose clutch.
Tighten clutch.
Problem
Reason
Remedy