Operation
BS 60/BS 70-2i
wc_tx000919gb.fm
24
4.4
To Start
See Graphic: wc_gr005331
4.4.1
Open throttle to full position
(c4)
. This will automatically turn on the
flow of fuel.
4.4.2
If machine is equipped, pump the purge bulb
(e)
6 to 10 times or until
you see fuel in bulb.
4.4.3
Close choke
(b1)
.
4.4.4
Pull starter rope
(a)
. Repeat until engine starts. Multiple pulls (typically
less than 5 pulls) may be required to start an engine:
•
that has not been run before.
•
that has not been run for a long period of time (a week or more.)
•
that has been run completely out of fuel.
•
in cold weather conditions.
4.4.5
Reduce throttle to idle
(c2)
or high idle
(c3)
position.
Note:
The engine is equipped with a low oil level shutoff switch. If the
engine stops running after 15-30 seconds, check the oil level in the oil
tank and add Wacker Neuson two-cycle oil or equivalent as necessary.
4.4.6
Gradually open the choke
(b2)
. Allow engine to warm until it will idle
with the choke fully open.
Note:
A warm up period of about one minute may be required in cold
weather.