Operation
T01006GB.fm
25
* Let loose of the safety starting crank immediately and stop the
engine if it should start turning in the wrong direction (smoke coming
from the air filter) after a back kick.
Wait until the engine stops before repeating the starting procedure.
5. The charge control lamp (27) must turn off immediately after the
engine has started running and the acoustic alarm has stopped.
Stop the engine immediately in case of eventual irregularities, then
locate the fault and repair it.
The machine will start vibrating as soon as the engine starts revving
up.
Note: Do not activate automatic decompression lever while the engine is
running.
6. Bring the engine up to maximum rpm’s and then check the air filter’s
service indicator (also see chapter on „Maintenance“); clean the
dry-type air filter if necessary.
i
Содержание 0610049
Страница 1: ...www wackergroup com Operator s Manual Vibratory plate DPU 6055 0109986en 005 04 2008 ...
Страница 2: ......
Страница 4: ...T00940GB fm 2 ...
Страница 50: ......
Страница 53: ......
Страница 54: ......