![Wacker Neuson 0008060 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/wacker-neuson/0008060/0008060_operators-manual_866546034.webp)
Maintenance
WP 1540A/AW
wpm_tx001130gb.fm
32
5.12 Troubleshooting
Problem / Symptom
Reason / Remedy
Plate does not develop full
speed. Poor compaction.
• Engine throttle control not completely open.
• Throttle control not adjusted correctly.
• Ground too wet, plate sticking. Allow soil to dry
before compacting.
• Drive belt loose or worn, slipping on pulleys. Adjust
or replace belt. Check that engine mounting bolts
are tight.
• Exciter bearings binding. Check condition and level
of oil in exciter. Add or change oil.
• Air filter clogged with dust, reducing engine perfor-
mance. Clean or replace air filter.
• Engine speed too low. Check engine speed with
tachometer. Adjust or repair engine to run at correct
speed. Refer to engine manual.
Engine running, no vibration
• Engine throttle not open.
• Drive belt loose or broken. Adjust or replace.
• Clutch damaged. Inspect and replace clutch.
• Engine speed too low. Check engine speed.
• Too much oil in exciter. Adjust oil to correct level.
Plate jumps or compacts
unevenly.
• Ground surface too hard.
• Shockmounts loose or damaged.