Machine Maintenance
The chart below lists basic machine maintenance.
Note:
When machine is being used in asphalt, it is highly
recommended that shockmounts are replaced every year or
after 300 hours of usage.
Daily
before
starting
After
first
20 hrs.
Every
2 weeks
or
50 hrs.
Every
month
or
100 hrs.
Every
year
or
300 hrs.
Check external hardware.
Check and adjust drive belt.
Inspect shockmounts for damage.
Replace shockmounts as needed.
Change exciter oil.