![WACKER Group EH 23/110/22 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/wacker-group/eh-23-110-22/eh-23-110-22_operators-manual_3105133011.webp)
T00145GB
9
MAINTENANCE
Maintenance schedule
Check all external screw connections for tight fit appox. 8 hours after first operation.
Component
Maintenance work
Maintenance interval
Feed cable
Check for perfect condition, change if
daily
defective.
Protective hood
Ventilations slits free of dirt, clean if necessary.
Tools
Check the shaft and cutting edges and, if necessary,
sharpen, reforge or replace.
Motor head
Regrease via grease nipple (see technicla data)
20 hours
Carbon brushes
Check for wear - if remaining length less than12 mm
80 hours
in spite of cut - out facility - replace.
Motor head
Check all screws tight fit - if necessary,
retighten.
Percussion system Dismantle, clean, regrease.
Tool holder
Check for wear.
Electric breaker
Maintenance - WACKER service station.
300 hours