Chapter 5, Operating Instructions: FF 206 Independent Fitting Mandrel Setup
E.H. Wachs
Part No. 16-MAN-01, Rev. 4-1109
47
Squaring the FF 206 on Squared Flange
1.
Place the alignment fixture over the mandrel shaft.
2.
Slide the alignment fixture firmly against the flange
face.
3.
Tighten the two brass-tipped screws to lock the align-
ment fixture in place.
Figure 5-34. The squaring plate automatically
squares the FF 206 to the pipe face.
4.
Tighten the drawbar nut.
Figure 5-35. Tighten the drawbar nut to clamp the
mandrel in the flange I.D.