Technical Manual
WDGA with CANopen-Interface
6 - WDGA object dictionary
© Wachendorff Automation GmbH & Co. KG
20
Rev.1.24
Object
No.
Name
Sub
Idx
Function
Data type
ro
rw
co
Map
Default
value
1010h
p. 68
Store
Parameters
00h
Unsigned8
co
no
04h
01h Save all parameters
Unsigned32
rw
0000 0001h
02h Save communication
param.
Unsigned32
rw
0000 0001h
03h Save application
param.
Unsigned32
rw
0000 0001h
04h Save manufacturer
param.
Unsigned32
rw
0000 0001h
1011h
p. 69
Restore
default
Parameters
00h Restores factory
settings.
Unsigned8
co
no
04h
01h Restore all param.
Unsigned32
rw
0000 0001h
02h Restore
communication
param.
Unsigned32
rw
0000 0001h
03h Restore application
param.
Unsigned32
rw
0000 0001h
04h Restore manufacturer
param.
Unsigned32
rw
0000 0001h
1014h
p. 32
COB-ID
Emergency
object
00h Defines the COB-ID
of the emergency
object (EMCY).
Unsigned32
rw
no
0000 0080h+
Node-ID
1015h
p. 33
Inhibit time
EMCY
00h Defines the minimum
pause (in 100 ms
steps) bet-ween
single EMCYs
Unsigned16
rw
no
0000h
1016h
p. 31
Consumer
heartbeat
time
00h Defines the time
frame within the
heartbeat consumer
awaits an incoming
heartbeat otherwise
triggering an EMCY.
Unsigned8
co
no
01h
01h Heartbeat-Consumer
cycle time
Unsigned32
rw
0000 0000h
1017h
p. 31
Producer
heartbeat
time
00h Defines the heartbeat
cycle time in steps of
1 ms. 0h = heartbeat
disabled.
Unsigned16
rw
no
0000h
1018h
p. 1
Identity
Object
00h
Unsigned8
co
no
04h
01h Vendor-ID
Unsigned32
co
1F02 0001h
02h Product Code
Unsigned32
co
5744 4741h
03h Revision Number
Unsigned32
i*
04h Serial Number
Unsigned32
i*
1020h
p. 38
Verify
Configura-
tion
00h The time of the last
configuration can be
logged here. If the
configuration was
changed after setting
this value, the object
is set to zero
autonomously.
Unsigned8
co
no
02h
01h Configuration date
Unsigned32
rw
0000 0000h
02h Configuration time
Unsigned32
rw
0000 0000h
Table 6.2: Object dictionary 1010h – 1020h