Technical Manual
WDGA with CANopen-Interface
7 - Object description
© Wachendorff Automation GmbH & Co. KG
33
Rev.1.24
ErrorCode
Field
Bit
Hex-
value
Error description
8120h + 8100h
Info field 1 (Byte3)
Low
Nibble
0
1h
active, no Error
1+2
6h
Bus-Warning
0+1+2 7h
Bus-Passive
8120h + 8100h
Info field 1 (Byte3)
High
Nibble
0
1h
Bit
1
2h
Stuffing-Error
0+1
3h
Form
2
4h
CRC
0+2
5h
Ack
Table 7.9: Info field list
The low nibble describes the CAN state, the high nibble gives further information about
the error.
The transmission of EMCY messages can be disabled by setting bit 31 (MSB) in object
1014h-00h.
By changing 1015h a minimum pause between two EMCYs can be defined (in steps
of 100µs).
7.4 Error Objects
7.4.1 Manufacturer status register
Interpretation of object 1002h (assignment bit - meaning, standard = 00h):
Bit:
7
6
5
4
3
2
1
0
Info: co
co
co
co
co
EEPROM* MT*
ST*(1)
Bit:
15
14
13
12
11
10
9
8
Info: ST*(8) ST*(7) ST*(6) ST*(5) ST*(4) ST*(3) ST*(2) ST*(1)
Bit:
23
22
21
20
19
18
17
16
Info: ST*(15) ST*(14) ST*(13) ST*(12) ST*(11) ST*(10) ST*(9) ST*(8)
Bit:
31
30
29
28
27
26
25
24
Info: MT*(9) MT*(8) MT*(7) MT*(6) MT*(5) MT*(4) MT*(3) MT*(2)
Table 7.10: Manufacturer status register
*= Error type (number) | for detailed definitions please contact our technical support.