Technical Manual
WDGA with CANopen-Interface
5 - General information about CAN
© Wachendorff Automation GmbH & Co. KG
17
Rev.1.24
Operational
Object
Communication enabled
SDO
yes
PDO
yes
NMT
yes
SYNC
yes
EMCY
yes
Heartbeat
yes
Device is in operational status and can send and receive PDOs.
Table 5.5: Available communication – Operational
Stopped
Object
Communication enabled
SDO
no
PDO
no
NMT
yes
SYNC
no
EMCY
no
Heartbeat
yes
The communication is almost completely disabled.
The device only reacts on NMT commands (e.g. start node).
Table 5.6: Available communication – Stopped
5.5 Heartbeat and Node-Guarding
There are two possible ways to supervise the operational availability of a CAN node
during operation.
Heartbeat
Node-Guarding
The heartbeat protocol is independent from the master. It is the recommended
mechanism. The device sends autonomous and cyclic a "life" message.
Wachendorff Automation recommends the use of the heartbeat
protocol.