Operating instruction BA_074_2020-01_10.00  Universal panel indicator PH5100

Page 3/15

  

Operating manual 

 

- 3 -    

BA_074e, Rev.1C5 

1. Introduction 

Dear valued Customer! 

Thank you for purchasing and using a product from our company. The universal digital panel meter 

PH5100 from LABOM Mess- und Regeltechnik GmbH could be used for a numerous number of 

applications. 

For getting the highest effort out of this unit, we kindly ask you to follow the below mentioned 

instructions: 

Every person who is involved with the installation or usage of this unit, must read carefully 

and understand the installation manual and safety instructions! 

2. 

Safety instructions 

2.1  General information 

To ensure the safe operation of this unit the instructions that appear in this manual must be strictly 

observed. In addition, when used all applicable legal and safety regulations for the respective 

application must be observed. The same applies correspondingly to the use of accessories.   

2.2   Intended usage 

Units from the PH5100 are used for collecting and displaying of a variaty of analogue sensor 

signals. Any other use is regarded not in accordance with the intended usage. 

The LABOM universal panel meters PH5100 are not meant to be used as sole safety 

means to prevent dangerous situations on machinery and installations. Machinery and 

installations must be so designed that fault conditions can not lead to harmful situations to 

operating personnel (e.g. by independent limit value switches, mechanical locking etc.). 

2.3   Qualified personnel 

Units from the LABOM universal panel meter PH5100 must only be operated in accordance with 

the technical specifications by qualified personnel. Personnel regarded qualified is familiar with the 

installation, assembly, putting into operation and operation of the units and possesses adequate 

professional qualification for the task. 

2.4   Remaining hazards 

Units from the LABOM universal panel meter PH5100 are state of the art and safe to operate. A 

risk of danger can occur when deployed and operated improperly by untrained personnel.  

In this manual remaining hazards are marked by the following warning symbol: 

2.5  Legal responsibilityh 

Liability for material defects and defects of this documentation, particularly for the accuracy, 

correctness, freedom of protection or third party rights, completeness and/or usability - except for 

willful misconduct or gross negligence - is excluded. 

This symbol indicates that non-observance of the safety guidelines may 

cause hazards to persons even serious injury or death and/or the 

possibility of property damage. 

Содержание PH5100

Страница 1: ...H Im Gewerbepark 13 27798 Hude Germany Hotline 49 4408 804 444 Fax 49 4408 804 100 e mail sales labom com www labom com Operating instruction BA_074_2020 01_10 00 Page 1 3 BA_074e Rev 1C5 info labom c...

Страница 2: ...on scale factor t ScF 6 4 9 Batch totalizing function 6 4 10 F1 and F2 function keys 6 4 11 Over flow alarm 7 4 12 Minimum and maximum 7 4 13 24 VDC auxiliary voltage source 7 4 14 Interface 7 5 Insta...

Страница 3: ...5100 are not meant to be used as sole safety means to prevent dangerous situations on machinery and installations Machinery and installations must be so designed that fault conditions can not lead to...

Страница 4: ...t Type CODE Measurement range Thermo couple J Range 110 C to 950 C 166 F to 1742 F Thermo couple K Range 150 C to 1370 C 238 F to 2498 F Thermo couple T Range 160 C to 400 C 256 F to 752 F Thermo coup...

Страница 5: ...he Minimum Differential Value It triggers when the value of the PV is below the point defined by ALrF SPA1 using alarm 1 as an example ALrF PV ALrF SPA1 ALrF PV ALrF SPA1 SPA1 positive SPA1 negative A...

Страница 6: ...stored in a non volatile internal memory and can also be presented at the indicator display by choosing TOTAL screen which is identified by the symbol TOT This symbol is always presented when the TOTA...

Страница 7: ...es up to 99999 99999 or 9999 99999 The flags HIGH and LOW identify if the part being displayed is the SP most significant part HIGH or the least significant part LOW The totalization alarm SP is defin...

Страница 8: ...pplication Figure 04 Auxiliary 24 Vdc usage example 5 3 Recommendations for the installation To minimize the pick up of electrical noise the low voltage DC connections and the sensor input wiring shou...

Страница 9: ...nsisting of assigning values to the parameters according to the desired behavior The user shall understand the importance of each parameter and determine a valid condition or a valid value for each on...

Страница 10: ...imum differential Alarm Referenz Totalization alarm SP decimal point SetPoint Alarm Alarm SP Value that defines the point of activation of the alarm outputs For the alarms programmed with the function...

Страница 11: ...it It defines the upper value of the indication range when the input types of 0 20 mA 4 20 mA 0 50 mV 0 5 V and 0 10 V are used avto r Defines the function to be executed by F1 and F2 keys No associat...

Страница 12: ...ferent from zero Protection Sets up the Level of Protection See Table 03 page 13 Frequency Frequency of the local electrical network Serial number 4 most significant digits Serial number 4 least signi...

Страница 13: ...nded for allowing the user to define a new password in the event of it being forgotten The Master Password doesn t grant access to all parameters only to the Password Change parameter PAS After defini...

Страница 14: ...0 2 of the span Input impedance Pt100 T C 0 to 50 mV 10 M 0 to 5 V 0 to10 V 500 k 4 to 20 mA 100 Measuring of the Pt100 3 wire type 0 00385 with compensation of the cable length max 50 meters excitat...

Страница 15: ...the device described therein 12 Disclaimer All technical content within this document can be modified without notice The content of this document is content of a recurring audit In losses due fire ea...

Отзывы: