4 Function modes and technical description
4.1
LED Indications
LEDs
Description of the LED function
GREEN + YELLOW
1.
Chasing light (over all LEDs):
The bootloader is active. No normal functions
are possible.
2.
All LEDs flash shortly every 6 s:
An internal data error was detected and cor-
rected automatically! The module still works regularly. To acknowledge the error
the module has to be cycle powered.
YELLOW
Both yellow LEDs flash oppositely every 1 s:
The nonvolatile stored parameters
are inconsistent! To acknowledge the error the data have to be saved with the SAVE
command or the corresponding button in the WPC. If the function of the module has
changed via the FUNCTION parameter, all parameters are deleted purposely and set
to default values. In this case the LEDs indicate no error, but a desired state. To
acknowledge please save.
GREEN
Identical to the READY output.
OFF:
No power supply or ENABLE is not activated
ON:
System is ready for operation
Flashing:
Error detected (e.
g. valve solenoid or 4… 20 mA).
Not active when SENS = OFF.
YELLOW
LED in the middle position = Current to the solenoid; the intensity is proportional to
the actual output current.
LED in the right position =
Power limitation; the LED indicates, whether the device
is in power limitation range or not.