VWR SCUCBI-0420 Скачать руководство пользователя страница 13

 Part number 20073, Rev 0 

13 

 

Treat  your  water- 

Though  this  is  not  always  practical,  softening  hard  water  can  do  much  to 

reduce deposits.  There are certain filters that can be installed to remove corrosive elements.  
If you are not sure of the proper water treatment, call a treatment specialist. 

Keep your equipment clean- 

Use proper cleaners at recommended strength.  Clean frequently 

to avoid build-up of hard stubborn stains. 

Rinse thoroughly - 

If chlorinated cleaners are used, you must rinse and wipe dry immediately.  

The sooner you wipe off standing water, the better.  After wiping the unit down, allow it to air 
dry. The oxygen helps maintain the stainless steels passivity film. 
Never use hydrochloric acid (muriatic acid) on stainless steel. 
  

Job 

Cleaning Agent 

Comments 

Routine Cleaning 

Soap, 

ammonia, 

detergent medallion 

Apply  with  cloth  or 
sponge 

Fingerprints & smears 

Arcal 

20, 

Lac-O-Nu 

Ecoshine 

Provides barrier firm 

Stubborn 

stains 

discoloration 

Cameo,  Talc,  Zud,  First 
Impression 

Rub  in  direction  of  polish 
lines 

Grease & fatty acids, blood 

Easy-off, 

DeGrease 

It 

Over Aid 

Excellent  removal  on  all 
finishes 

Grease & oil 

Any  good  commercial 
detergent 

Apply  with  a  sponge  or 
cloth 

Restoration – Passivation 

Benefit, Super Sheen 

 

 

Passive Film Breakdown 

 

Corrosion  on  metals  is  everywhere.    We  recognize  it  quickly  on  iron  and  steel  as 
unsightly  yellow/  orange  rust.    Such  metals  are  called  “active”  because  they  actively 
corrode in the natural environment. 

 

Contrary to popular belief, Stainless Steels are susceptible to rusting. The first signs are 
on the microscopic level.  If you were to look at them under a microscope or through a 
magnifying glass, you would see small pits and cracks will grow and deepen while all the 
time exuding unsightly, red-orange rust. More severe and visible cracking can also take 
place. 

 

Stainless  steels  are  protected  by  a  thin  layer  of  chromium  oxide,  and  it  important  to 
keep  that  film  of  chromium  oxide  intact.  If  the  passive  film  of  your  stainless  steel  has 
been broken, you are subject to corrosion and rust. The integrity of the chromium oxide 
can be compromised by: 
-

 

Mechanical abrasion

 from steel pads, brushes, and scrapers. 

-

 

Hard  Water 

leaves  mineral  deposits behind  that,  if  left to dry  will  break down  the 

passive layer and rust your stainless steel. 

-

 

Chlorides

 are in water, food, and table salt, but most prominently in cleaning agents.   

 

 

 

Содержание SCUCBI-0420

Страница 1: ...f delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being unpacked When concealed damage is discovered stop unpacking immediately and contact the carrier immediately to report the claim and request an inspection This should be done as soon as possible and in any case must b...

Страница 2: ... SERVICE please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left OR right upper wall of the unit For convenience you may want to record the following information here for easy access in the future Model number __________________________________ Serial number ____________...

Страница 3: ...ry receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along with a formal request for an inspection report Follow up with a phone call Their contact information can be found on the carrier s web site The second type of shipping damage is concealed damage This t...

Страница 4: ...his cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial Data plate for voltage cycle phase and amp requirements before making connection VOLTAGE SHOULD NOT VARY MORE THAN 5 FROM SERIAL PLATE RATINGS A separate circuit is recommended to prevent possible loss of product due to over loading or failure of other equipment on the same circuit PROTECT THE CIRCUIT WI...

Страница 5: ...pecially if the weather is very hot This is normal The motor compressor will cycle normally as soon as the excess heat has been removed TEMPERATURE CONTROL NOTE The control is preset at the factory to provide the desired air and product temperatures inside of the unit and requires no further adjustment Please contact the manufacturer s Technical Service Department before making any adjustments to ...

Страница 6: ...anged through the bottom front grill Please ensure the bottom front grill is free from dust or any object that may block the airflow When loading the top shelf avoid blocking the evaporator fan s if installed There should be at least 4 inches of clearance around the fan to allow proper air flow Do not overload the unit Maximum suggested load is about 75 of the chamber volume Additionally the load ...

Страница 7: ...vides the following functions Red LED for visual indication of an alarm condition Beeper for audible indication of an alarm condition A preprogrammed 5 minute delay from the time a set point is attained until an alarm condition is declared This prevents spurious alarms for things like door openings Operating Mode The Electronic Temperature Control normally displays the current interior temperature...

Страница 8: ...w Pon The control keys are now unlocked and you can perform the programming functions below Adjusting the temperature control set points NOTE The temperature control set points are preset at the factory to provide the desired air and product temperatures inside of the unit and require no further adjustment Please contact the manufacturer s Technical Service Department before making any adjustments...

Страница 9: ...display Press the UP or DOWN keys several times to cycle through the parameters until CF is displayed Press SET to display the current setting either C for Celsius or F for Fahrenheit Use the UP or DOWN key to choose the desired setting Press SET again to lock it in Press SET and UP to return to Operating Mode To change the Hi or Low Alarm set points press SET and DOWN keys for 3 seconds to enter ...

Страница 10: ...ed the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerator s rear or side walls Evaporator is blocked by frost or ice Remove the products unplug the refrigerator or freezer power and allow the unit to defrost If the problem still exists call for service Appliance runs too long Prolong door openings Control ...

Страница 11: ...above 40C 104F Stop using immediately The display shows LL and the compressor does not run The ambient temperature is below 40C 40F Stop using immediately MOISTURE DURING THE SUMMER SEASON The amount of moisture condensation or high humidity related issues increase during the summer and in most cases will self resolve when the weather cools down Please note a refrigeration system does NOT generate...

Страница 12: ... not use commercial household cleaners ammonia or alcohol to clean handles Use a soft cloth to clean smooth handles Do not use a dry cloth to clean smooth handles STAINLESS STEEL CARE AND CLEANING Use the proper tools When cleaning stainless steel surfaces take care to use non abrasive tools Soft cloths and plastic scouring pads will not harm the steel s passive layer Stainless steel pads may be u...

Страница 13: ...t removal on all finishes Grease oil Any good commercial detergent Apply with a sponge or cloth Restoration Passivation Benefit Super Sheen Passive Film Breakdown Corrosion on metals is everywhere We recognize it quickly on iron and steel as unsightly yellow orange rust Such metals are called active because they actively corrode in the natural environment Contrary to popular belief Stainless Steel...

Страница 14: ...gging to avoid electrical hazard DO NOT ADJUST THE TEMPERATURE CONTROL Remove the product and leave the door open while defrosting the freezer Place towels in the bottom of the freezer to catch the frost When all frost has fallen remove the towels Defrosting tips If the frost is soft remove it with a plastic scraper If the frost is glazed and hard fill deep pans with hot water and place them insid...

Страница 15: ...be paid by the customer ADDITIONAL THREE YEAR COMPRESSOR WARRANTY In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship under normal use and service for a period of three 3 additional years from the end of the initial two 2 year warranty period but not to...

Страница 16: ...nt damage during transit or installation fire flood or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage caused by the storage of any corrosive material that comes in contact with the interior or exterior portions of the cabinet or the use of spark producing eq...

Отзывы: