VWR Flow Through Скачать руководство пользователя страница 2

 

Table of Contents 

 

Section 1 – General Information 

1.1 Warranty 

1.2 Unpacking 

1.3 Package 

Contents 

1.4 

Description of Models 

1.5 Specification 

Chart 

 

Section 2 – Operations 

2.1 Power 

2.2 

Safety Overload Warning 

2.3 

Choice of Fluids 

2.4 Operating 

Procedure 

For Immersion Coolers 

2.5 Operating 

Procedure 

For Flow-Through Coolers 

2.6 Application 

Notes 

 

Section 3 - Trouble Shooting 

3.1 Required 

Maintenance 

3.2 

Problem & Solution chart 

 

Section 4 - Service and Technical Support 

 

 

 

 

 

 

 

 

This symbol marks chapters and sections of this instruction manual which are particularly relevant 
to safety.  When attached to the unit, this symbol draws attention to the relevant section of the 
instruction manual 

 

 

Содержание Flow Through

Страница 1: ...Operator Manual Flow Through Coolers Immersion Coolers 110 064 Rev C 05 03...

Страница 2: ...ng Procedure For Immersion Coolers 2 5 Operating Procedure For Flow Through Coolers 2 6 Application Notes Section 3 Trouble Shooting 3 1 Required Maintenance 3 2 Problem Solution chart Section 4 Servi...

Страница 3: ...r other causes not arising out of defects in material or workmanship There are no warranties expressed or implied including but not limited to those of merchantability or fitness for a particular purp...

Страница 4: ...ith a copper tube within a tube heat exchanger The fluid to be cooled is circulated through the space between the tubes while the refrigerant evaporates to produce cooling inside the inner tube The fl...

Страница 5: ...and wait 10 minutes before restarting 2 3 Choice of Fluids In order to select a fluid for low temperature use the viscosity of a fluid at low temperatures as well as its freezing point must be consid...

Страница 6: ...r pump 5 Set the circulator s temperature control to the desired temperature When the temperature stabilizes the circulator s heater should cycle to maintain the set temp 6 Turn the Cooler s power swi...

Страница 7: ...ltage Avoid extension cords that can cause voltage drops 3 See Sect 3 1 Required Maintenance Check for airflow exiting the back of the unit Air vents should not be closer than 3 in from a wall or unit...

Страница 8: ...ssor valves may produce high pitch buzzing sound 12 Check power Unit s power switch should be illuminated Section 4 Service and Technical Support If you have followed the troubleshooting steps and you...