VWR Advanced Melting Point Apparatus Скачать руководство пользователя страница 4

3

s

afety

 I

nstrUctIons

Please read the entire instruction manual before operating the Melting Point Apparatus.

WARNING!  DO NOT use the Melting Point Apparatus in a hazardous 

atmosphere or with hazardous materials for which the unit was not designed. 

Also, the user should be aware that the protection provided by the equipment 

may be impaired if used with accessories not provided or recommended by 

the manufacturer, or used in a manner not specified by the manufacturer.
Always operate unit on a level surface for best performance and maximum 

safety.
CAUTION! To avoid electrical shock, completely cut off power to the unit 

by disconnecting the power cord from the unit or unplug from the wall outlet. 

Disconnect unit from the power supply prior to maintenance and servicing.
Spills should be removed promptly, after the unit has cooled downDO NOT 

immerse the unit for cleaning. DO NOT operate the unit if it shows signs of 

electrical or mechanical damage.
The main supply power cord provided with this product is rated to safely 

handle the products electrical load under the stated environmental conditions. 

DO NOT replace the cord with an inadequately rated main supply cord.
The Melting Point Apparatus is designed to be operated in dry conditions. 

DO NOT place anything other than the appropriate capillary tubes in the oven 

opening.
CAUTION! The Melting Point Apparatus is not explosion proof. Use caution 

when unit is on or when heating volatile materials.
Earth Ground - Protective Conductor Terminal
Alternating Current

s

tandards

 & r

egUlatIons

The manufacturer hereby declares under it’s sole responsibility that the construction 

of this product conforms in accordance with the following standards:
Safety standards:

CAN/CSA C22.2 No. 61010-1

CAN/CSA C22.2 No. 61010-2-010

UL 61010-1

EN 61010-1

EN 61010-2-010
EMC standards:

FCC Part 15 Subpart B

ICES-003

IEC 61326-1

EN 61326-1

CISPR 11

EN 55011

Содержание Advanced Melting Point Apparatus

Страница 1: ...1 Instruction Manual Basic Melting Point Apparatus Advanced Melting Point Apparatus ...

Страница 2: ...rcanlab com warranty for Canadian residents For your reference make a note of the serial number date of purchase and supplier here Serial Number Date of Purchase Supplier Table of Contents Package Contents 1 Warranty 1 Installation 2 Maintenance Servicing 2 Environmental Conditions 2 Equipment Disposal 2 Safety Instructions 3 4 Standards Regulations 3 4 Specifications 5 Basic Control Panel 6 Opera...

Страница 3: ...removed promptly after the unit has cooled down DO NOT use a cleaning agent or solvent on the front panel which is abrasive or harmful to plastics nor one which is flammable Always ensure the power is disconnected from the unit prior to any cleaning If the unit ever requires service contact your VWR representative Intended Use The VWR Melting Point Apparatus intended for general laboratory use Saf...

Страница 4: ...immerse the unit for cleaning DO NOT operate the unit if it shows signs of electrical or mechanical damage The main supply power cord provided with this product is rated to safely handle the products electrical load under the stated environmental conditions DO NOT replace the cord with an inadequately rated main supply cord The Melting Point Apparatus is designed to be operated in dry conditions D...

Страница 5: ...s il semble avoir subi des dommages électriques ou mécaniques Le cordon d alimentation principal fourni avec ce produit est calibrée pour supporter en toute sécurité le chargement des produits électriques dans les conditions définies NE PAS remplacer ce cordon avec un cordon d alimentation principal mal classé Les appareil à point de fusion sont conçus pour fonctionner à sec Ne pas verser d eau d ...

Страница 6: ...50 60 Hz 120V 0 75 amps 85 watts 230V 0 50 amps 110 watts Fuses 5mm x 20mm 250V 5 amp quick acting Temperature range ambient 5 C to 400 C Temperature accuracy 1 Temperature resolution 1 C 0 1 C Heat up time to 400 C 6 minutes Ramp rate 2 C min 0 1 C to 10 C min Memory N A 1000 tests 4 temperatures per test Controls see page 6 see page 9 Ship weight 4lbs 1 81kg 4 5lbs 2 04kg ...

Страница 7: ...utton Start heating to set temperature start ramping to melt temperature view data C Stop button Stop ramping and return to set temperature stop viewing data turn heater off return to standby mode D Up and Down Arrows Scroll through temperature values to set scroll though date and time to set scroll through data to view Basic Melting Point Apparatus Control Panel A B C D ...

Страница 8: ...and the heater will turn off to prevent indefinite heating 5 Insert Sample into Oven a Insert 1 3 capillary tube s containing the prepared sample s closed end first into the opening on top of the oven Wait 30 seconds to stabilize before continuing to Step 6 6 Start Ramping to Melt Temperature a After the capillary tubes have been inserted into the oven press Start to start heating to the melt temp...

Страница 9: ...a new set temperature is required use the Up and Down Arrows to select a new temperature Repeat Steps 4 8 to continue testing with the new set temperature 11 If testing is complete Press Stop after Step 8 to turn the heater off and return to standby mode 12 Unplug unit when it is not in use Basic Melting Point Apparatus Operating Instructions Cont d SET DATE AND TIME BASIC ONLY 1 Hold Set button a...

Страница 10: ...ve Melt 2 save Melt 3 save Melt 4 view data save data to unit save data to USB B Stop button Stop ramping and return to set temperature turn heater off move on to next prompt return to standby mode C Up and Down Arrows Scross through temperature values to set Scroll through date and time to set Scroll through ramp rate to set Scroll through saved data D Numeric keys enter temperature ramp rate tes...

Страница 11: ... tighten the knob to hold the arm in place 3 Standby Mode a When the unit is plugged in the date time and actual temperature will be shown on the LCD screen This is the unit in standby mode 4 Set Temperature a Press the Select button b Use the numeric buttons to select a temperature or Up and Down Arrows c When the correct temperature is displayed on the screen press Select 5 Set Ramp Rate a After...

Страница 12: ...press Stop to move on to the next prompt 11 Save Data to Unit a After Stop is pressed Save Data to Unit will be shown on the display b To move on to the next prompt without saving data to the unit press Stop c To save the data for the test that was just completed press Select When saving is complete display will move on to next prompt 12 Save Data to USB a After data is saved to the unit or Stop i...

Страница 13: ...ayed hold Stop and Up Arrow buttons at the same time for 3 seconds 7 When SPC Temp is displayed enter the experimental melting point determined in Step 2 8 Press Select to exit calibration mode and return to normal heating CALIBRATE TO EXTERNAL TEMPERATURE PROBE 1 Turn unit on 2 Insert Calibration USB Accessory 3 Set desired temperature 4 When Set Temp Reached is displayed insert external temperat...

Страница 14: ...s error cannot be fixed by the end user Please contact your VWR representative for repair E2 Heating element failure This error cannot be fixed by the end user Please contact your VWR representative for repair E3 Unit cannot reach set point Use Single Point Calibration instructions to calibrate to external temperature device Advanced option only If problem persists please contact your VWR represen...

Страница 15: ...ck Start Guide Label 549622 00 4 Control Board 349323 00 5 Display Board 349320 00 6 Power Supply 349322 00 7 Power Entry Module Assembly 349330 00 8 Rubber Foot 4 530052 00 Detachable 92 234cm power cord 120V 330100 00 Euro plug 330101 00 Basic Melting Point Apparatus Replacement Parts ...

Страница 16: ... 00 3 Lower Arm Bottom 249404 00 4 Lower Arm Top 249408 00 5 Adjustment Knob Large 549620 00 6 Membrane Switch 349326 00 7 Control Board 349323 00 8 Display Board 349320 00 9 Power Supply 349322 00 10 Power Entry Module Assemly 349330 00 11 Rubber Foot 4 530052 00 Detachable 92 234cm power cord 120V 330100 00 Euro plug 330101 00 ...

Страница 17: ...LC Accessories for Melting Point Apparatus Accessory Type Description Compatibility Part Number Capillary Tube pack of 100 Capillary tubes with one end open Basic Advanced 949VWMPCAP Cooling Block Metal block for oven to reduce cooling time Basic Advanced 949VWMPCOOL Calibration USB Allows single point calibration to an external temperature device Advanced 949VWCALUSB ...

Отзывы: