background image

 

19 

 

time (or press the button 

Stop

 ) end. Press the button 

Cancel

 to return to the main 

interface. 

 

Time 

Single cleaning time, range: 1 ~ 300s, interval 1s adjustment or set to "-" 

continuous injection until manual stop. 

Stop injection/recycling/cleaning 

Main interface, if the injection/recycling/cleaning is in progress, press the button 

Stop

 

button on the right to end. 

 

 

 

Содержание 634-1138

Страница 1: ...re Control System European Catalogue Number EU UK CH Plug 634 1138 A 1101 CONTROLLER SIPPER EU UK CH Plug 634 1139 A 1001 CONTROLLER SIPPER WITH CONSTANT TEMPERATURE EU UK CH Plug 634 1140 A 1201 CONTROLLER CONSTANT TEMPERATURE Version 1 0 1 Issued 16 June 2020 ...

Страница 2: ...2 Legal Address of Manufacturer Europe VWR International bv Researchpark Haasrode 2020 Geldenaaksebaan 464 B 3001 Leuven 32 16 385011 www vwr com Made in China ...

Страница 3: ...bols and conventions 11 Product Specifications 11 Getting Started 13 Using the instrument 14 Operation 16 Temperature Control 16 Sipper 17 System settings 20 Technical service 21 Warranty 21 Compliance with local laws and regulations 22 Equipment disposal 22 Local VWR offices in Europe and Asia Pacific 23 ...

Страница 4: ...voltage area Danger Do not use the device if it is damaged especially if the main power cable way is in any damaged or defective Repairs may only be carried out by the service technicians from your authorized contractual partners The device must be connected to a power outlet that has a protective ground connection If the equipment is used in a manner not specified by the manufacturer the protecti...

Страница 5: ...Temperature 1PC 10mm Flowing Quartz Cuvette 1PC Sample Chamber Baffle including constant temperature interface injection hole 1PC Silicone Pipe with Limit Ring 1m Inner hole diameter φ2 Outer diameter φ4 1PC Silicone pipe 700mm Inner hole diameter φ2 Outer diameter φ4 1PC Constant Temperature Control Cable 1PC Power Cords EU UK CH Plug 1PC Instruction Manual 1PC ...

Страница 6: ...meter φ2 Outer diameter φ4 1PC Silicone pipe 700mm Inner hole diameter φ2 Outer diameter φ4 1PC Power Cords EU UK CH Plug 1PC Instruction Manual 1PC Configuration list of A 1201 Description Quantity Constant Temperature Controller 1PC 10mm Single Cell Holder with Constant Temperature 1PC Sample Chamber Baffle including constant temperature interface 1PC Constant Temperature Control Cable 1PC Power...

Страница 7: ...ontractual partners Description The A 1001 series Constant Temperature Automatic Injection Controller is specially developed to meet the needs of some applications of our UV Vis spectrophotometer It is divided into 3 models according to different functions Model A 1001 Sipper with Temperature Control model A 1101 Sipper model A 1201 Temperature Control 1 2 4 5 7 8 9 6 3 10 12 11 13 ...

Страница 8: ...trol Interface 12 Out Hole 13 Thermostatic Single Sample Holder Installation Placement Place the instrument on the stable table carefully Install thermostatic single sample holder Turn off the power of the instrument Remove the original sample holder and remove the original door insert As shown in the figure attach the thermostatic sample holder and tighten the two screws shown by the arrows ...

Страница 9: ... constant temperature control cable The instrument is turned off As shown in the figure insert one end of the constant temperature control cable into the thermostat interface on the outside of the spectrophotometer door insert and the other end into the constant temperature control interface on the back of the controller 1 Constant Temperature Control Port 2 Constant Temperature Control Cable 3 Co...

Страница 10: ...insert the injection end of the flow cuvette label 2 One end of the sample discharge pipe label 5 is connected to the sample end of the flow cuvette label 2 and the other end is passed through the sample hole of the cover plate 1 Injection Pipe 2 Flowing Cuvette 3 Sample Container 4 Waste Collection Container 5 Sample Discharge Pipe 1 5 2 3 4 ...

Страница 11: ...ion CAUTION This symbol indicates risks associated with hot surfaces Product Specifications Model A 1001 A 1101 A 1201 Function Sipper with Temperature Control Sipper Temperature Control Temperature Range 10 90 0 1 C interval adjustable 10 90 0 1 C interval adjustable Temperature Control Accuracy 0 1 0 1 Temperature Control appointment time 0 5 10h 0 5h interval adjustable 0 5 10h 0 5h interval ad...

Страница 12: ...op Sample Holder 10mm Single Cell Holder with Constant Temperature 10mm Single Cell Holder 10mm Single Cell Holder with Constant Temperature Display 4 3 Inch TFT Color Touch Screen Communication Interface Serial port RS232 1 USB B 1 Language 10 language switching English French German Spanish Portuguese Italian Russian Chinese Japanese Korean Power Supply 100 240V AC 50 60Hz 60VA 100 240V AC 50 60...

Страница 13: ...be activated by touch To make a selection use your finger or a capacitive stylus to press or slide the screen Press or slide the buttons terms and icons on the screen to make selections inputs and actions Note Do not press a screen with a sharp object such as a ballpoint pen tip Do not place any objects on top of the screen to avoid damaging or scratching the screen Touch screen operation Press Cl...

Страница 14: ...and slide the icon to a position to change the setting value Using the instrument Main Interface The main interface is divided into two parts the left part is the temperature control area and the right part is the injection control area A 1001 1 2 3 4 5 6 5 6 ...

Страница 15: ...emperature Appointment time process Sipper control state Sipper speed Temperature control start Stop temperature control Recycle the sample in the flow cuvette after the end of the measurement Cleaning the flow cuvette Inhale the sample into the flow cuvette 1 2 3 4 1 2 3 4 5 6 ...

Страница 16: ...pop up the temperature control parameter interface press the button to set the temperature control parameters according to the requirements Press the button OK the temperature control module start working Press the button Cancel to return to the main interface Temperature Set temperature range 10 C 90 C 0 1 C interval adjustment Mode The way to control the temperature ...

Страница 17: ... Main interface if temperature control is turned on press the button Stop on the left to end the temperature control Sipper Start sipper 1 Place the suction end of the silicone tube in the sample solution 2 Main interface press the button Injection on the right to pop up the injection control parameter interface press the button to set the injection parameters according to the requirements Press t...

Страница 18: ...ameters according to the requirements Press the button OK to start recycling reach the set time or press the button Stop end Press the button Cancel to return to the main interface Time Time for single sample recycle range 1 300s interval 1s adjustment or set to continuous injection until manual stop Cleaning the flow cuvette 1 Place the suction end of the silicone tube in the cleaning solution 2 ...

Страница 19: ...he main interface Time Single cleaning time range 1 300s interval 1s adjustment or set to continuous injection until manual stop Stop injection recycling cleaning Main interface if the injection recycling cleaning is in progress press the button Stop button on the right to end ...

Страница 20: ...splay when there is no operation for a period of time to save energy and extend the life of the display Press the icon on the standby tab to turn it on off Turn beep on off when pressing the button on off Press the icon on the sound tab to turn the beep sound on off Language selection The instrument supports 10 language switching English French German Spanish Portuguese Italian Russian Chinese Jap...

Страница 21: ... present VWR will at its option and cost repair replace or refund the purchase price of this product to the customer provided it is returned during the warranty period This warranty does not apply if the product has been damaged by accident abuse misuse or misapplication or from ordinary wear and tear If the required maintenance and inspection services are not performed according to the manuals an...

Страница 22: ...ed waste Instead it s your responsibility to correctly dispose of your equipment at lifecycle end by handling it over to an authorized facility for separate collection and recycling It s also your responsibility to decontaminate the equipment in case of biological chemical and or radiological contamination so as to protect from health hazards the persons involved in the disposal and recycling of t...

Страница 23: ...VWR International Northern Ireland Ltd Orion Business Campus Northwest Business Park Ballycoolin Dublin 15 Tel 353 01 88 22 222 Email sales ie vwr com Italy VWR International S r l Via San Giusto 85 20153 Milano MI Tel 39 02 3320311 02 487791 Email info it vwr com Korea VWR International 17 Daehak 4 ro Yeongtong gu Suwon si Gyeonggi do Tel 82 31 645 7256 saleskorea avantorsciences com Middle East ...

Отзывы: