GP, Explosion-Proof and FMS Lab Refrigerators and Freezers

Intended Use    |    3

Intended Use

The General Purpose refrigerator/freezer described in this 
manual is for professional use only.

The Flammable Materials Storage and Explosion-Proof 
refrigerators/freezers described in this manual are for use in 
the storage of flammable inventory/samples. These models 
have been listed to the appropriate standards.

These products are intended for use in research for the 
storage of samples or inventory in the following temperature 
ranges:

Refrigerators 

33.8°F to 53.6°F (+1°C to +12°C)

Freezers 

-4°F to 10.4°F (-20°C to -12°C)

These units are not considered medical devices and have 
therefore not been registered with a medical device regulatory 
body (e.g. FDA): that is, these have not been evaluated for the 
storage of samples for diagnostic use or for samples to be

re-introduced to the body. 

Note: 

Do not store corrosive materials in these units. Any 

damage which occurs due to storage of corrosives will not be 
covered under warranty claims.

Corrosive Materials Requiring Refrigerated or Frozen Storage:

Only use models rated as Corrosion Resistant.

Corrosion Resistant does not mean Corrosion Proof – 
Care in storage is still required.

Store only corrosive reagents/samples which truly need 
reduced temperature storage.

Flammable corrosive materials require Flammable 
Materials Storage or Explosion-Proof models labeled for 
the storage of corrosives

Containers must be wiped clean of moisture and 
chemical residue before being introduced into the unit 
and upon return from use.

Containers must be sealed with either vinyl tape or 
Parafilm®.

Reagents/samples which release HX (X= F, Cl, Br, I) on 
contact with moisture (e.g. Acyl halides, Organosilyl 
halides etc.) are particularly damaging to metals.

Volatile amines will react with HX depositing salts which 
will lead to corrosion of metal surfaces.

Volatile organic acids can exacerbate metal surfaces 
already compromised, be sure these are securely sealed.

Refrigerated compartments are cool or cold areas but 
they are not to dry seal your reagents and samples.

Bleach solutions release chlorine gas which can react 
with other volatiles in the cooling chamber or directly 
attacks metal surfaces.

Periodically clean the interiors, clean up spills or leaking 
containers. 

Failure to take precautionary actions may lead to damage 
not covered by warranty claims.

Parafilm® is a registered trademark of Bemis Company, 
Oshkosh, WI.

Содержание 10ECEEVWA

Страница 1: ...VWR General Purpose Explosion Proof and Flammable Materials Storage Laboratory Refrigerators and Freezers Installation and Operation 057 658 00 Rev C February 2019...

Страница 2: ...tice VWR makes no representations or warranties with respect to this manual In no event shall VWR be held liable for any damages direct or incidental arising from or related to the use of this manual...

Страница 3: ...pose Refrigerator Freezer 7 Unpacking and Inspection 8 Shipping Carton 8 Visible Loss or Damage 8 Concealed Loss or Damage 8 Operating Standards 9 Installation 10 Selecting a Location 10 Leveling the...

Страница 4: ...o Save Energy 13 Safety Tips 13 Maintenance 14 Cleaning the Unit 14 Cleaning Interior Exterior Door Gaskets 14 Cleaning the Condenser 14 Troubleshooting 15 Wiring Diagram 16 End of Life Care 17 Warran...

Страница 5: ...Models 1 Models The table below shows the units covered in this operation and installation manual by model number Table 1 Applicable Models Refrigerators and Freezers Explosion Proof 10ECEEVWA Flamma...

Страница 6: ...al Code unless otherwise noted Alert Signals ON OFF Safety Alert Important operating instructions To reduce the risk of injury or poor performance of the unit Read the user manual before putting the e...

Страница 7: ...Resistant Corrosion Resistant does not mean Corrosion Proof Care in storage is still required Store only corrosive reagents samples which truly need reduced temperature storage Flammable corrosive mat...

Страница 8: ...ess steel refrigeration components that are more resistant to attack from corrosive vapors than are aluminum or epoxy coated aluminum It is important to note that Explosion Proof models must be connec...

Страница 9: ...rior notice Explosion Proof units require being hard wired into the building electrical system and therefore require a qualified electrician to install as per the local electrical requirements and NEC...

Страница 10: ...h helping to lower operating costs The interior is made of porcelain enameled steel or ABS plastic VWR Scientific offers the largest selection of FMS units All models are delivered with 3 wire line co...

Страница 11: ...color 10LCEEVWA Refrigerator Chamber Dimensions H x W x D inches cm 38 25 x 19 75 x 18 25 97 2 x 50 2 x 46 4 cm Freezer Chamber Dimensions H x W x D inches cm 18 25 x 18 x 11 25 46 3 x 45 7 x 28 6 cm...

Страница 12: ...o adequately describe such external evidence of loss or damage may result in the carrier s refusing to honor your damage claim The form required to file such a claim will be supplied by the carrier IM...

Страница 13: ...ment in a Pollution Degree 21 and Over voltage Category II environment These units are designed to operate under the following environmental conditions Indoor use Altitude up to 2000 m 6512 feet Maxim...

Страница 14: ...al to that specified on the data plate WARNING For personal safety this unit must be properly grounded before use Flammable Materials Storage and General Purpose units must be connected to a grounded...

Страница 15: ...tinue adding smaller amounts of water until a thick gravy consistency is achieved NOT WATERY Discard any material that becomes too stiff to use Never attempt to restore workability by stirring in more...

Страница 16: ...ll occur in approximately 30 minutes However the sealing compound requires a minimum of 8 hours above 32 F 0 C to develop sufficient strength to withstand explosions Note Wires must be kept separated...

Страница 17: ...eft at this setting for the nighttime period return temperature control to original setting when the room thermostat is returned to its normal setting Restart Procedure If unit is unplugged or turned...

Страница 18: ...ld soap detergent and lukewarm water can be used for cleaning the interior exterior and door gaskets with a soft clean cloth Rinse with clean water and dry thoroughly before reconnecting and turning o...

Страница 19: ...ure over 109 F 43 C Door opening frequency is high Defrost unit Clean the condenser with a dry brush or vacuum A leak around the door gasket will allow cold air to escape This causes unit to work hard...

Страница 20: ...am GP Explosion Proof and FMS Lab Refrigerators and Freezers Wiring Diagram THERMOSTAT BLK WHT 120V BLK 240V OVERLOAD PROTECTOR RED C M S M S I C RELAY COMPRESSOR Figure 6 Wiring diagram for 10FCEEVWA...

Страница 21: ...nit Some suggestions are listed below 1 Remove items and defrost unit Be sure to clean up any biological safety hazards 2 Remove the cabinet door to help prevent entrapment inside of a unit 3 Have a c...

Страница 22: ...electrical power surges iv improper storage and handling of the products v use of the products in combination with equipment or software not supplied by VWR or vi installation maintenance repair serv...

Страница 23: ...a 91 22 6716 2200 China 800 810 5118 400 650 5118 Japan 81 3 5826 1616 Australia 61 39757 4300 Austria 43 1 801 40 0 Belgium 32 53 73 42 41 France 33 2 2803 2180 Germany international 49 6184 90 6000...

Страница 24: ...lding One Suite 200 100 Matsonford Road Radnor PA P O Box 6660 United States www vwr com Find out more at www vwr com 2019 VWR Inc All rights reserved All trademarks are the property of VWR and its su...

Отзывы: