background image

             

VVDN_DT4CP2U_Quick_Start_Guide

 

                            

Rev. A1

 

11 

CONFIDENTIAL 

 

 Power Oring Card: 

1.8

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание DT4CP-2U

Страница 1: ... 2015 VVDN Technologies All Rights Reserved DT4CP 2U Storage Server Quick Start Guide Revision A1 ...

Страница 2: ... The Open Server The Open server provides an established framework to demonstrate the accelrated communication process It provide the solution for communication with higher network connectivity and powerful security using encryption methodology It offering powerful unified communication using scale out and storage option The storage appliance is designed to provide features that include data compr...

Страница 3: ...T4CP2U_Quick_Start_Guide Rev A1 3 CONFIDENTIAL Revision History Date Rev No Description By 29 April 2015 A0 01 2U Quick Start Guide Initial Draft VVDN 29 April 2015 A0 01 Updated i NOR FLASH ii Rear View VVDN ...

Страница 4: ...OARD MANAGEMENT CONTROLLER BMC 14 PREPARING BOARD 14 3 1 FEATURES 14 3 2 UPGRADING IMAGE ON BMC 14 3 3 3 3 1 Create tftp server 14 3 3 2 Network Configuration 15 STEPS TO FLASH THE IMAGE ON BMC 15 3 4 4 T4240MFCS 16 PREPARING BOARD 16 4 1 FEATURES 16 4 2 PORT MAP 17 4 3 NOR FLASH 18 4 4 SWITCH SETTING FOR SERVER1 AND SERVER2 FOR NOR FLASH 19 4 5 NOR FLASH 19 4 6 SWITCH SETTINGS AND SET UP CONFIGUR...

Страница 5: ...telecom datacom data center storage applications and wireless infrastructure applications A Dual T4240 based Data center Storage appliance offering a powerful unified communication solution with up to 80G of external network connectivity SRIO inter chip connectivity and multiple SAS HDD s and PCIe based SSD s The storage appliance is designed to provide features that include data compression de du...

Страница 6: ...VVDN_DT4CP2U_Quick_Start_Guide Rev A1 6 CONFIDENTIAL Top View 1 3 ...

Страница 7: ...VVDN_DT4CP2U_Quick_Start_Guide Rev A1 7 CONFIDENTIAL Rear View 1 4 ...

Страница 8: ...en power led is blinking slow 9 12 second Reset button Sequence Press Reset button for right t4240 reset release reset button when power led is blinking fast 3 6 seconds Press Reset button for left t4240 reset release power button when power led is blinking slow 9 12 second Button 0 3 sec 3 6 sec Fast blink power led 6 9 sec 9 12 sec Slow blink power led Power No Action Power off on right T4240 No...

Страница 9: ...VVDN_DT4CP2U_Quick_Start_Guide Rev A1 9 CONFIDENTIAL PCIe and SAS Interface 1 6 ...

Страница 10: ...VVDN_DT4CP2U_Quick_Start_Guide Rev A1 10 CONFIDENTIAL SD Card 1 7 ...

Страница 11: ...VVDN_DT4CP2U_Quick_Start_Guide Rev A1 11 CONFIDENTIAL Power Oring Card 1 8 ...

Страница 12: ...S29GL01GS11TFIV1 4 Module Micro SD Card 8GB 2 SANDISK 8GB Usd 5 IC uC AST1250 ARM9 400MHz LFBGA 408 2 ASPEED TECHNOLOGY INC AST1250A1 GP 6 IC 88E1512 Single Port Gigabit Ethernet PHY QFN 56 4 MARVELL 88E1512 A0 NNP2I000 7 Module SSD PCIe 3 0 400GB 2 5 Inch 8 INTEL SSDPE2MD400G401 8 Module SAS 100GB 8 HGST HUSSL4010BSS600 9 Module SFP Transceiver 10G Dual LC DDM 8 FINISAR FTLX8571D3BCV 10 IC TUSB20...

Страница 13: ...FI PCIe x4 5G PCIe x4 5G AC to DC PSU 1 AC to DC PSU 2 Local Power Supply Generation PCIe 3 PCIe 1 SRIO 2 SERDES 2 A SERDES 2 B SERDES 2 C SERDES 2 D SERDES 2 A SERDES 2 B SERDES 2 C SERDES 2 D SRIO 1 SRIO 1 AC Input 2 AC Input 1 PCIe SSD x4 PCIe Bridge SRIO 2 PCIe 3 PCIe x4 5G PCIe 1 PCIe Bridge PCIe SSD x4 SRIO x4 5G SRIO x4 5G SAS Controller Multiplexer SAS SATA HDD x3 SAS SATA HDD x4 PCIe x4 5...

Страница 14: ...g image on BMC 3 3 To get the images from server it is necessary to configure the server This configuration involves Create the tftp server Network configuration 3 3 1 Create tftp server Install the tftp server by using the following command sudo apt get install xinetd tftpd tftp Create etc xinetd d tftp and write the following tftp configurations default off description The tftp server serves fil...

Страница 15: ...t the BMC and let the kernel up Set the ip of the BMC by using ifconfig For e g ifconfig eth0 down ifconfig eth0 192 168 0 45 up Check whether the host is connected or not using ping command To use tftp host e g laptop and BMC should be in same domain NOTE Both server and BMC in 192 168 0 x domain ping 192 168 0 81 If connection is done goto tmp directory This can be done by cd tmp Get the image f...

Страница 16: ...data bits 8 Number of stop bits 1 Flow Control Hardware none 4 Push the power button on the front side of chassis The board will boot and show the u boot console messages on CPU UART Features 4 2 Some key features of the DT4CP2U are Freescale QorIQ Processing Platform a QorIQ T4240 dual communication processors with 24 e6500 cores per T4240 Memory Subsystem a DDR3 SDRAM 1 6 DIMM slots supports 4 G...

Страница 17: ...d is one of the available booting options for Dual T4240 Communications Platform See Program SD card and SD card image upgrade Port Map 4 3 The table below shows how ETH matches to Linux and U boot For Server 1 Label on Front Panel Port in u boot Port in Linux FMAN address Comments 1G Port 1 FM1 DTSEC1 FM1 MAC1 0xfe4e0000 SGMII 1G Port 2 FM1 DTSEC2 FM1 MAC2 0xfe4e2000 SGMII 1G Port 3 FM1 DTSEC3 FM...

Страница 18: ...fe4e6000 SGMII 10G Port 1 FM2 TGEC1 FM2 MAC9 0xfe5f0000 10G XFI 10G Port 2 FM2 TGEC2 FM2 MAC10 0xfe5f2000 10G XFI 10G Port 3 FM1 TGEC2 FM1 MAC10 0xfe4f2000 10G XFI 10G Port 4 FM1 TGEC1 FM1 MAC9 0xfe4f0000 10G XFI NOR FLASH 4 4 This section explains programming the images in NOR flash and the switch settings for server 1 and 2 for NOR flash Commands for programming images in NOR flash tftp 1000000 ...

Страница 19: ...2 for NOR Flash 4 5 For server 1 DIP Switch 7 8 9 10 11 12 SW7 Off Off Off Off Off Off SW8 Off Off Off On Off On For server 2 DIP Switch 7 8 9 10 11 12 SW5 Off Off Off Off Off Off SW6 Off Off Off On Off On NOR FLASH 4 6 When SD Card is used as a booting device NOR Flash can be tested at u boot prompt with following commands NOR Flash is the primary booting option which contains RCW U boot U boot e...

Страница 20: ...VVDN_DT4CP2U_Quick_Start_Guide Rev A1 20 CONFIDENTIAL Switch Settings and set up configuration 4 7 ...

Страница 21: ...de Rev A1 21 CONFIDENTIAL 4 7 1 Switch Default settings SD Card boot This boot default boot from SD card its switches is set below For Server 1 For Server 2 DIP Switch 1 2 3 4 5 6 SW7 Off Off Off Off Off Off SW8 Off On On On On On ...

Страница 22: ...ard Copy uImage into boot directory of rootfs 8 Flash dtb file into SD card Copy t4240mfcs dtb into boot directory of rootfs 9 Plug SD card into mmc slot of board 10 Boot the board and catch u boot prompt 11 Command line parameter to be set at u boot prompt setenv bootcmd setenv bootargs root dev mmcblk0p1 rw rootdelay 5 console consoledev baudrate mmcinfo ext2load mmc 0 1 loadaddr boot bootfile e...

Страница 23: ...3A BA B0 setenv eth11addr 00 10 F3 3A BA B1 setenv eth6addr 00 10 F3 3A BA B8 setenv eth7addr 00 10 F3 3A BA B9 setenv eth8addr 00 10 F3 3A BA AA setenv eth3addr 00 10 F3 3A BA A1 setenv eth4addr 00 10 F3 3A BA A0 setenv eth5addr 00 10 F3 3A BA BF setenv ethaddr 00 11 22 33 44 55 setenv eth1addr 00 10 F3 3A BA AB setenv eth2addr 00 10 F3 3A BA AC setenv eth15addr 00 10 F3 3A BA BC saveenv 13 Run f...

Страница 24: ...t t ext2 dev mmcblk0p1 mount c Copy image into SD card by using scp scp uImage root board ip home root mount boot scp t4240mfcs dtb root board ip home root mount boot umount home root mount d Reboot the board Refer front view Reboot the Right T4240 Board Server 1 Press Reset button for right t4240 reset release reset button when power led is blinking fast 3 6 seconds Reboot the left T4240 Board Se...