14
1.4.5.1 The control panel includes:
• Digital temperature and humidity meter
• Temperature control with control range +30 to +125 °С
• Three separated control circuits for tubular heating elements of the
steam generator
• One control circuit for tubular heating elements, which heat stones
(air)
The control panel provides:
• Delay of Electric heater switching on up to 24 hours with a
15-minute interval
• Automatic complete switching off of the Electric heater after
6 hours, during which CP elements were not touched (factory
settings)
Options of the information presentation on LCD of the control unit are shown below:
6
0
%
*
*
*
3
0
.
5
O
N
7
0
6
0
%
*
3
0
.
5
O
F
F
7
0
60 is a current relative air humidity
30.5 is a current air temperature
Fig. 5
CP appearance