1. VULKAN

 

 

Technical specifications:

Components of the radiator:

Way of packing – 2 cartons:

 

Carton 1:

 

the body with the cover and the base (no.5 and 

9), socket screws M 5 mm - 3 pcs. (no.8), legs (no.10), roof 

fixed on the flame tube (no.12), flat (no.13), mounting pin 

(no.14) and manual (optionally the connection set)

 

Carton 2:

 

flame tube with a cover (no.4), roof (no.2), 6 

sleeves fi14mm (no.3), and 3 wing nuts (no.1)

The order of assembly: 

- Remove the flame tube from Carton 2 with the cover 

(no.4) and unscrew the wing nuts (no.1) 

- Remove the visor (no.2), and three sleeves (no.3), leave 

the remaining three on the screws

- Remove the visor from Carton 1 (no.12) and place it on 

the screws with sleeves (no.3) on the flame pipe with a 

cover (no.4), place the remaining three sleeves (no.3) and 

the visor (no.2), and tighten them with the wing nuts (no.1)

- Remove the bottom of the radiator from Carton 1 – body 

with the cover (no.5)

- Screw the legs to the base (no.9) (no.10) which are 

included in the packaging. Please note that in case of 

uneven surfaces you should adjust the level by loosening 

or tightening the legs (no.10)

 

- Fasten the heater to the ground (no.13 and 14)

- Apply the flame tube with the mounted cap on the flange 

of the bottom of the radiator (no.6 on no.7) and tighten 

with the socket screws (no.8) using the Allen key attached 

to the packaging

- Once again check the stability of the radiator adjusting 

the feet (no.10)

model 

VULKAN 30

VULKAN 37

VULKAN 50

device category

I3B/P

I3B/P

I3B/P

gas type

Propane Butane 

Propane Butane PLBP

Propane Butane 

pressure 

30mbar

37 mbar

50 mbar

power

8,0kW

8,5 kW 

7,5kW

gas use

0,50kg/h 

0,59 kg/h 

0,51 kg/h

max cable length

1,5 mb (40/10 bar ø10)

1,5 mb (40/10 bar ø10)

1,5 mb (40/10 bar ø10)

working pressure 

30mbar BG, CY, CZ, DK, EE, 

FI, GR, HU, HR, IT, LT, LV, MT, 

NL, NO, RO, SE, SI, SK, TR,

37 mbar PL 

50 mbar AU DE

nozzle

1,4

1,4

1,00

(1)

(2)

 

A

B

1

2

3

5

6

 

7

 

8

1

2

3

9

10

6

7

8

11

12

12

4

13

14

Содержание Etna 30

Страница 1: ...Read the user manual before use USER MANUAL Producer Komin Flex Sp z o o 43 200 Pszczyna ul G rno l ska 1 www kominflex com pl vulkan com pl...

Страница 2: ...ration of the valve 1 note fumes use the device in well ventilated rooms 4 note temperature do not touch the heated surfaces keep a minimum distance from combustible items 2 3 note exploitation only b...

Страница 3: ...e position 2 PILOT and pressing the knob wait for approx 1 5 minute return to the starting position press the know slightly and turn it to the right clockwise to the starting position 1 OFF wait for a...

Страница 4: ...adiator from Carton 1 body with the cover no 5 Screw the legs to the base no 9 no 10 which are included in the packaging Please note that in case of uneven surfaces you should adjust the level by loos...

Страница 5: ...the packaging Please note that in case of uneven surfaces you should adjust the level by loosening or tightening the legs no 10 Apply the flame tube with the mounted cap on the flange of the bottom p...

Страница 6: ...the flame tube with the cap on the bottom part of the radiator and tighten with three supplied screws Once again check the stability of the radiator adjusting the legs no 4 model Helena 30 Helena 37 H...

Страница 7: ...no 5 Screw the legs to the base no 9 no 10 included in the packaging Please note that in case of uneven surfaces you should adjust the level by loosening or tightening the legs no 10 Apply the flame t...

Страница 8: ...materials should be at least 1 2 metres When operating the radiator under a roof or in built up areas you should provide sufficient ventilation at least 20 of the open volume The radiator should be op...

Страница 9: ...uld always be washed with plenty of water and after drying a preservative used THE MOST COMMON FAULTS AND THEIR REPAIR CUSTOMER SUPPORT AND SERVICE All questions concerning the repair maintenance and...

Страница 10: ...quality 7 For proper operation of the VULKAN terrace radiator it is necessary to maintain a periodic replacement of the connection set ie the low pressure controller and the hose it is recommended to...