Vulcan-Hart Wolf VCRB25 Скачать руководство пользователя страница 3

 

3

 - 

INSTALLATION, OPERATION AND CARE OF 

MEDIUM DUTY GAS CHARBROILERS 

 

GENERAL 

 
Gas  Countertop  Charbroilers  are  designed  for  commercial  use  only  and  feature  fast, 
efficient  gas  heat.    Each  burner  is  controlled  by  an  adjustable  gas  valve.  Cast  radiants 
are  located  directly  above  each  burner  to  maintain  uniform  t emperature.  Radiants  are 
easily removed for cleaning when cool.  
 
Heavy-duty,  cast  iron  top  grates  are  reversible  to  allow  all  or  part  of  the  cooking  grid 
surface  to  be  level  or  sloped.    Grooves,  cast  in  the  top  grates,  permit  fat  runoff  and 
reduce  flaring  when  tilted  towards  the  front.    A  grease  drawer  is  provided  to  collect  fat 
run-off; it opens to the front for inspection or drain -off. 
 
 

 
 

Model 

Number Of Burners 

BTU/hr Input Rating 

VCRB25 / WCRB25 

58,000 

VCRB36 / WCRB36 

87,000 

VCRB47 / WCRB47 

116,000 

 

 

INSTALLATION 

 
UNPACKING 
 

This charbroiler was inspected before leaving the factory. The carrier assumes full responsibility for the 
safe delivery upon acceptance of the shipment. Check for possible shipping damage immediately after 
receipt.   
 
If the charbroiler is found to be damaged, complete the following steps: 
 
1.  

Carrier must be notified within 5 business days of receipt. 

2.      

Carrier’s local terminal must be notified immediately upon discovery (note time, date, and 

            who was spoken to), and follow up and confirm with written or electronic communication. 
3.        All original packing materials must be kept for inspection purposes. 
4.        The charbroiler cannot have been moved, installed, or modified. 
5.         Notify Vulcan Customer Service immediately at 800-814-2028. 
 
Carefully unpack your charbroiler and make sure that no parts are discarded with 
packaging material. A pressure regulator designed to operate with the  broiler has been 
supplied and must be installed before the  charbroiler is placed into service (Refer to GAS 
PRESSURE REGULATOR INSTALLATION in this manual). 

 

Содержание Wolf VCRB25

Страница 1: ...UTURE USE FORM F 38307 9 15 INSTALLATION OPERATION MANUAL FOR MEDIUM DUTY GAS CHARBROILERS VCRB47 MODELS VCRB25 VCRB36 VCRB47 WCRB25 WCRB36 WCRB47 For additional information on Vulcan or to locate an...

Страница 2: ...IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER...

Страница 3: ...This charbroiler was inspected before leaving the factory The carrier assumes full responsibility for the safe delivery upon acceptance of the shipment Check for possible shipping damage immediately...

Страница 4: ...ns of ANSI Z223 1 NFPA 54 latest edition and NFPA 96 latest edition in the United States of America or CAN CSA 149 1 latest edition and CAN CSA149 2 latest edition in Canada and approved by the author...

Страница 5: ...LEVELING It is important that the charbroiler is level front to back and left to right Areas of uneven heat distribution will occur on an unleveled unit The charbroiler is equipped with adjustable leg...

Страница 6: ...r propane gas is recommended With all units operating simultaneously the manifold pressure on all units should not show any appreciable drop When testing the gas supply piping system if test pressures...

Страница 7: ...ting check all joints in the gas supply line for leaks Use soap and water solution Do not use an open flame CASTER EQUIPPED CHARBROILERS Charbroilers mounted on stands with casters must use a flexible...

Страница 8: ...provide a slight yellow tip on the flame Air shutters on the main burners must be individually adjusted to provide a blue flame All traces of yellow should be adjusted out of the burner flame The char...

Страница 9: ...n gas shut off valve OFF Make sure all individual burner valves are off before relighting PREHEATING THE CHARBROILER Allow the charbroiler to preheat for 30 minutes Rub grates with cooking oil before...

Страница 10: ...off or clean debris from unit This will cause a buildup of heat that can potentially damage and warp components of the charbroiler MAINTENANCE The charbroiler and its parts are hot Use care when oper...

Страница 11: ...adjusted B Appliance is not level side to side C Improperly adjusted burner Uneven heat front to back A Appliance is not level front to back B Faulty ventilation C Improperly adjusted burner Pilot ou...

Страница 12: ...12 NOTES...

Страница 13: ...12 REMARQUES...

Страница 14: ...avant vers l arri re A L appareil n est pas au niveau de l avant vers l arri re B La ventilation est d fectueuse C Le br leur est mal r gl Panne de la veilleuse d allumage A La veilleuse d allumage e...

Страница 15: ...d bris de l l ment Cela provoquera une augmentation de la chaleur qui peut potentiellement endommager ou d former les composants du gril ENTRETIEN Le gril et ses pi ces sont chauds Faites attention l...

Страница 16: ...SES Pour fermer compl tement Fermez le robinet d arr t principal du gaz Assurez vous que toutes les soupapes individuelles des br leurs sont ferm es avant de rallumer PR CHAUFFAGE DU GRIL Pr chauffez...

Страница 17: ...Les obturateurs d air des principaux br leurs doivent tre r gl s individuellement afin d offrir une flamme bleue Toutes les traces de jaune devraient tre limin es d e la flamme des br leurs Le gril e...

Страница 18: ...nt l allumage v rifiez tous les joints dans la conduite d alimentation en gaz pour les fuites Uti lisez une solution d eau et savon Ne pas utiliser une flamme nue GRILS MUNIS DE ROULETTES Les grils su...

Страница 19: ...el et de 28 cm CE pour le gaz propane Avec tous les l ments fonctionnant en m me temps la pression d admission sur tous les l ments ne devrait pas d montrer une baisse notable Lorsque vous valuez la t...

Страница 20: ...que le gril soit mis niveau de l avant vers l arri re et de la gauche vers la droite Il se produira des zones o la distribution de la chaleur sera in gale dans un appareil qui n est pas mis niveau Le...

Страница 21: ...applicables des normes ANSI Z223 1 NFPA N 54 et NFPA N 96 ditions les plus r centes aux tats Unis d Am rique ou les normes CAN CSA 149 1 et CAN CSA149 2 ditions les plus r centes au Canada le tout suj...

Страница 22: ...LATION D BALLAGE Ce gril a t inspect avant de quitter l usine En acceptant sa livraison le transporteur prend l enti re responsabilit de le livrer en toute s curit Imm diatement apr s la livraison v r...

Страница 23: ...ECT E FERMEZ LES UNIT S DU ROBINET D ARR T PRINCIPAL ET CONTACTEZ VOTRE COMPAGNIE DE GAZ OU VOTRE FOURNISSEUR DE GAZ LOCAL AFIN D OBTENIR DU SERVICE POUR VOTRE S CURIT NE PAS ENTREPOSER OU UTILISER DE...

Страница 24: ...00 North Point Blvd Baltimore MD 21222 GARDER CE MANUAL POUR UNE UTILISATION FUTURE FORMULAIRE F 38307 9 15 MANUEL D INSTALLATION ET D EMPLOI POUR GRILS AU GAZ FONCTION MOYENNE VCRB47 MODELS VCRB25 VC...

Отзывы: