![Vulcan-Hart VI2 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/vulcan-hart/vi2/vi2_service-manual_1056585020.webp)
INDUCTION COOKERS - ELECTRICAL OPERATION
20
SEQUENCE OF OPERATION
1.
Cooktop has power applied.
A.
Circuit boards have power applied to them
all the time the unit is plugged in and the
receptacle is live.
B.
Low voltage board is monitoring input from
controller board.
2.
Turn control knob clockwise to desired cooking
level.
A.
Cooling fans turn on.
B.
If indicator light blinks, it indicates no pan
is detected and cooktop will shut off after 3
minutes.
1)
Cooktop is in stand-by mode and
must be reset to continue operating.
2)
Cooling fans turn off.
3)
Reset cooktop by turning control knob
to OFF, then back ON to desired
cooking level.
C.
When pan is in place and indicator is on,
cooktop is heating.
3.
When cooking is finished, turn control knob
counterclockwise to OFF.
A.
Appliance fans may continue to run until
unit is cooled.
4.