![Vulcan-Hart VI2 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/vulcan-hart/vi2/vi2_service-manual_1056585011.webp)
INDUCTION COOKERS - REMOVAL AND REPLACEMENT OF PARTS
11
EMI BOARD
WARNING: UNPLUG UNIT BEFORE SERVICING.
CAUTION: Certain components in this system
are subject to damage due to electro-static
discharge during field repairs. A Field Service
Kit is available to prevent this damage. This
Field Service Kit must be used anytime a
component or circuit board is handled. Specific
instructions are included with the kit.
1.
Remove the high voltage board as outlined
under “HIGH VOLTAGE BOARD”.
2.
Disconnect the lead wires to the EMI board.
3.
Push in the tabs of the pins that secure the EMI
board and remove the board from the mounting
plate.
4.
Reverse the procedure to install.
5.
Adjust power output as outlined under
“POWER OUTPUT ADJUSTMENT”.
FUSE ON EMI BOARD
WARNING: UNPLUG UNIT BEFORE SERVICING.
1.
Remove fuse using needle nose pliers or small
screwdriver.
THERMISTOR, TENSION
SPRING AND SUPPORT
WARNING: UNPLUG UNIT BEFORE SERVICING.
1.
Remove the top cover as outlined under “TOP
COVER”.
2.
Unplug thermistor from the high voltage board.
3.
Depress thermistor support assembly and
rotate 90°.
4.
Withdraw thermistor support assembly from
inverter coil.
5.
Reverse the procedure to install.
NOTE: Apply generous amount of thermal
compound to top of thermistor support assembly.