10
220/380, 240/415 VOLT VS/VM RANGES AND VR RANGES WITH OVEN
3 PHASE LOAD
NOMINAL AMPS PER LINE WIRE
TOTAL KW PER PHASE
240/415 VOLT
KW
3 PHASE
1 PHASE
MODEL
CONN.
X-N
Y-N
Z-N
X
Y
Z
X
Z
VR1,2,5
21.7
7.7
5
9
32
21
38
32
58
VR1,2,5 / VB73
27.7
10.7
8
9
45
33
38
45
71
VS,VM1,2,5
15
5
5
5
21
21
21
21
42
VS,VM1,2,5 / VB73
21
8
8
5
33
33
21
33
54
VR3,6,7
20.7
6.7
5
9
28
31
38
28
59
VR3,6,7 / VB73
26.7
9.7
8
9
41
33
38
41
71
VS,VM3,6,7
14
4
5
5
17
21
21
17
42
VS,VM3,6,7 / VB73
20
7
8
5
29
33
21
29
54
VR4
18.7
6.7
4
8
28
17
33
28
50
VR4 / VB73
24.7
9.7
7
8
41
29
33
41
62
VS,VM4
12
4
4
4
17
17
17
17
34
VS,VM4 / VB73
18
7
7
4
29
29
17
29
46
VOLTAGE FROM ANY PHASE TO NEUTRAL NOT TO EXCEED 250 VOLTS
220/380, 240/415 VOLT VRC RANGES WITH CONVECTION OVEN
3 PHASE LOAD
NOMINAL AMPS PER LINE WIRE
TOTAL
KW PER PHASE
3 PHASE
1 PHASE
KW
220/380V
240/415V
MODEL
CONN.
X-N
Y-N
Z-N
X
Y
Z
X
Y
Z
X
Z
VR1C,2C,5C
22
6.2
6.2
9.6
33
25
33
34
26
34
34
60
VR1C,2C,5C/VB73
28
9.2
9.2
9.6
40
38
40
41
39
41
41
80
VR3C,6C,7C
21
6.2
6.2
8.6
31
23
33
32
24
34
32
58
VR3C,6C,7C/VB73
27
9.2
9.2
8.6
37
35
38
38
37
39
38
76
VR4C
19
5.2
5.2
8.6
31
21
33
32
22
34
32
56
VR4C/VB73
25
8.2
8.2
8.6
37
33
38
38
34
39
38
73
VOLTAGE FROM ANY PHASE TO NEUTRAL NOT TO EXCEED 250 VOLTS
220/380, 240/415 VOLT VEX AND VMX RANGES WITHOUT OVEN
NOMINAL AMPS PER LINE WIRE
LOAD
TOTAL KW 1PH,3-WIRE
2-WIRE 1PH,3-WIRE
2-WIRE
KW/PHASE
CONN.
220/380 220
240/415
240
1 PHASE
MODEL
220/380 240/415
L1
L2
L1
L1
L2
L1
L1-N
L2-N
VEX,VMX1
4.2
5
9.6
9.6
19.3
10.5
24
21
2.5
2.5
VEX2,VMX2
4.2
5
19.3
—
19.3
21
—
21
—
—
VEX3,VMX3
3.4
4
7.8
7.8
15.6
8.5
19
17
2.0
2.0
"VB73" in above charts denotes an electric elevated broiler installed over the range.
Содержание VEX
Страница 2: ...2...
Страница 5: ...5 VEX1 VMX1 VMX3 VEX3 VMX2 VEX2 VM1 VM2 VULCAN RANGE CONFIGURATIONS PL 51130 2...