background image

[  10  ]

VULCAN GAS RANGES RG-6 OPEN BURNER

VULCAN CATERING EQUIPMENT (PTY)LTD

[  11  ]

REV5-03-2012  /  VFM06

Open Top – 6 x 27,000kJ / H x 130 diameter

VULCAN CATERING EQUIPMENT (PTY)LTD

Item No.

Stores Ref.No.

Description

Qty

14

3107 - 49

Jet / Ventury mount bracket

0

14

3107 - 52

Brass elbow M10 / M16 with nuts

6

15

3107 - 53

Jet nozzle (M 10 male) 

6

16

3107 - 50

Pilot / thermocouple mount bracket

0

16

3107 - 54

Burner body / ventury elbow

6

17

3107 - 47

cast iron burner body chromium plated

6

18

3107 - 46

Cast iron flame spreader chromium plated

6

19

3106 - 11

Oven burner

1

20

3700 - 15

cast iron grate

3

21

3700 - 16

cast iron spider

6

22

3129 - 01

Oven jet

1

23

3107 - 51

G31 Pilot burner

6

PREVENTATIVE MAINTENANCE:

1.   do a routine check on general appearance and moving parts.

2.   check that no screws and nuts have worked loose.

3.   Check pilots and flame burners.

4.   When burners require cleaning, remove the cast iron grate and spider.
5.   Remove the burners by lifting them off of the support pins.
6.   clean the burner with warm water soap and a soft cloth. The burner should be dry 

and obstruction free when replacing it. 

7.   Gas Leak testing should be done annually and/or whenever the unit is reconnected 

to the main gas supply.

8.   always inspect the hose for cuts,cracks,or excessive wear before use. damaged 

hoses must be replaced with suitable type which meets the national standards for 

the country of use (South africa: SanS 1156-2 or BS3212). The length of the hose 

shall not exceed 1.5m.

Method to check for gas leakage is as follows : 

1.   Ensure the area is well ventilated.

2.   Confirm that control knob is in OFF position.

3.   Mix up a solution of soap and water to a 50/50 ratio.
4.   Open the main gas control valve.
5.   Mix up a solution of soap and water to a 50/50 ratio.

Figure 1

To Reach air adjustments 

on Top Burners.

1

2

3

CONTROLS AND SPARE PARTS FOR  

RG-6 GAS OPEN BURNER  RANGE

6.   Methodically brush the solution onto all the gas system joints, including all the valve 

connections, hose/pipeconnections, and regulator connections.

7.   The formation of bubbles indicates a gas leak.
8.   Turn off the gas supply and re-tighten all joints where there are bubbles.
9.   Repeat the test.
10.  If bubbles apear again do not use the unit. contact you supplier or service agent for 

assistance.

11.  Never use an open flame to test for gas leaks at any time.

Burners of the oven: 

The  flame  of  the  burner  should  be  a  soft  blue, 

showing no yellow. If the flames are harsh or have 

yellow tops (see figure 1). Lift and slide back oven 

sole  plate  onto  door  and  carry  out  adjustment. 

correct  this  by  un-screwing  (no.1)  adjusting 

the primary air intake to the burner (no.3) in or 

out  until  optimum  setting  is  found  as  indicated 

above. When the air sleeve ( no.3) is at optimum 

position, re-tighten screw (no.1).

Oven: 

L.P. Gas has fixed aeration, adjustment is only necessary for Natural Gas.

Slide back oven sole plate into position after adjustments have been carried out.

Thermocouple: 

To replace thermocouple in the oven, remove the oven sole plate, the bottom front panel 

and the right hand control panel. Unscrew the thermocouple from the flame failure valve 

and release the probe from the bracket on the pilot burner. Remove the thermocouple 

and replace; do not overtighten. Check that the flame impinges on the probe and that the 

flame remains burning when the valve knob is released.

Reassemble Panelling.

Oven Door: 

check that the door moves freely and oil bearing surfaces every three months.

Open Top:  

Remove cast iron grate and spider, make the required adjustment.

Содержание RG-6

Страница 1: ...an catering Equipment Branches and dealers 3 Parts Ordering Service Information 4 Prior to Installation of Equipment 4 Heat Settings 4 cleaning Process 4 Trouble Shooting 5 Installation 5 Operation 6 Line drawing 8 Spares 9 Preventative Maintenance 10 Safety 12 VULCAN GAS RANGES RG 6 OPEN BURNER ...

Страница 2: ...quipment Dealer for replacement Important Information For The User This appliance may only be installed by a registered LP Gas installer All registered installers are issued with a card carrying their registration number Ask to be shown the card before allowing the installation work to commence and make a note of the installer QCC number Upon completion of the installation the installer is require...

Страница 3: ... the unit is closer to the wall then the wall must be fire proof 3 The unit must be installed in a well ventilated area 4 Remove the plastic material protecting the stainless steel panels 5 Position the unit Check with a spirit level and bring to correct level using the floor adjusters on the legs 6 A gas cock must be incorporated in the supply pipe and fitted close to the unit A gas regulator gov...

Страница 4: ... if pilot fails to light 4 When the control knob is turned to the first setting HIGH the burner will be ignitted by the pilot burner See drawing to see which knob operates which burner 5 For the second setting LOW depress and turn knob in a anti clockwise until it slots into position 6 To shut down the burners turn the controls clock wise until is locks in position pilot will still stay lit 7 When...

Страница 5: ...e M4 pin 1 2 3114 17 Ignitor wire 1 3 3114 23 Ignitor for minisit 1 4 3114 24 Minisit valve 100 340 1 5 3114 26 Minisit black knob 1 6 dn 5969 Oven door 1 7 dn 5969 7 Oven door hinge plates 2 8 3114 19 Thermocouple 600mm long for top burners 6 9 3114 14 Thermocouple 900mm long for oven 1 10 3135 19 Gas cock knob 6 11 3115 18 Gas cock 3 8 6 12 3109 18 Pilot burner 3 way 1 13 3848 02 door counter we...

Страница 6: ...Open the main gas control valve 5 Mix up a solution of soap and water to a 50 50 ratio Figure 1 To Reach Air Adjustments on Top Burners 1 2 3 CONTROLS AND SPARE PARTS FOR RG 6 GAS OPEN BURNER RANGE 6 Methodically brush the solution onto all the gas system joints including all the valve connections hose pipeconnections and regulator connections 7 The formation of bubbles indicates a gas leak 8 Turn...

Страница 7: ...st iron grate and spider and observe the flame it should be a soft blue flame showing no yellow if the flame is harsh or has yellow tips correct this by adjusting the air intake of the burner To reach the air adjustments open the access panel above the oven a 6mm Hex locking screw should be unscrewed slightly and the adjusting sleeve moved to the optimum position then the screw tightened again DO ...

Отзывы: