INSTALLATION CODES AND STANDARDS

For proper installation procedures in the United States of America, refer to:

1. State and local codes.

2. National Fuel Gas Code, ANSI-Z223.1 (latest edition). Copies may be obtained from The

American Gas Assn., Inc., 1515 Wilson Blvd., Arlington, VA 22209.

3. National Electrical Code ANSI/NFPA-70 (latest edition). Copies may be obtained from The

National Fire Protection Assn., Batterymarch Park, Quincy, MA 02269.

In Canada, refer to:

1. Local codes.

2. CAN/CGA-B149.1 Installation for Natural Gas Burning Appliances and Equipment

(latest edition).

3. CAN/CGA-B149.2 Propane Installation Code (latest edition), available from The Canadian

Standards Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.

ASSEMBLY

Backsplash

1. Remove the backsplash components from the crating materials.

2. Check the backsplash component parts against the list below to ensure that all the required

parts for the backsplash installation have been obtained.

• If any parts are missing, contact your dealer or closest parts depot immediately.

Backsplash Component Parts

3. Assemble the required components as shown in Fig. 2.

4. Lift the assembly up and slide the channels into the space provided at the rear of the range –

this may require two people.

MODELS

MG24C

MG36C

MG48C

Std. 4" (10 cm) Std. 11" (27 cm) Std. 11" (27 cm)

High

High

High

Backsplash (1)

Backsplash (1)

Backsplash (1)

Backsplash

Backsplash

Backsplash

Channel (2)

Channel (2)

Channel (2)

Heat Shield (1)

Heat Shield (1)

Heat Shield (1)

Fig. 2

Содержание MG24C

Страница 1: ...Y P O BOX 696 LOUISVILLE KY 40201 0696 TEL 502 778 2791 FORM 35607 06 03 INSTALLATION OPERATION MANUAL MODEL MG24C CARRABBA S MG SERIES GAS RESTAURANT MODULAR RANGE MODEL MG24C ML 135500 MG36C ML 1355...

Страница 2: ...ORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUT OFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FL...

Страница 3: ...stallation Codes and Standards 5 Assembly 5 Leveling 7 Gas Connections 7 Testing the Gas Supply System 8 Flue Connections 8 Lighting and Shutting Down Pilots 8 OPERATION 9 Controls 9 Preheating 9 Clea...

Страница 4: ...ompany immediately LOCATION CAUTION The equipment area must be kept free and clear of combustible substances The 28 000 BTU burner input range must have a minimum clearance from combustible constructi...

Страница 5: ...The Canadian Standards Association 178 Rexdale Blvd Etobicoke Ontario Canada M9W 1R3 ASSEMBLY Backsplash 1 Remove the backsplash components from the crating materials 2 Check the backsplash component...

Страница 6: ...order to clear the flue box Be sure the backsplash is resting evenly and the channel holes are lining up with the holes provided in the right and left hand body side see Fig s 3 4 Fig 3 Fig 4 Fig 5 6...

Страница 7: ...e range This regulator must be field installed by a qualified installer Natural gas regulators are preset for 5 0 W C Water Column propane gas regulators for 10 0 W C 1 Locate 3 4 1 9 cm gas connectio...

Страница 8: ...construction and installation of ventilating hoods may be obtained from the standard Vapor Removal from Cooking Equipment NFPA No 96 latest edition available from The National Fire Protection Associa...

Страница 9: ...they burn in A crust on top of the hot top range looks unsightly and slows down cooking speed because it reduces the flow of heat to the utensil Empty the grease pan daily or as often as necessary CA...

Страница 10: ...flue vent every six months for obstructions SERVICE AND PARTS INFORMATION To obtain service and parts information concerning this modular range contact the Vulcan Hart Service Agency in your area refe...

Отзывы: