LG400

FREE STANDING GAS FRYER

OVERALL

WORKING

TANK

FRY COMP.

APPROX.

MODEL

WIDTH

DEPTH

HEIGHT

HEIGHT

SIZE

BTU/HR.

CAPACITY

SHP.WT.

LG400

15

1

/

2

"

30

1

/

4

"

47

1

/

8

"

36

1

/

4

"

14" x 14"

120,000

45 - 50 lbs.

210 lbs./91 kg

IMPORTANT

1. A combination valve with pressure regulator is provided with

this unit.

Natural Gas 4.0" (102 mm) W.C.

Propane Gas 10.0" (279 mm) W.C.

2. An adequate ventilation system is required for Commercial

Cooking Equipment. Information may be obtained by writing

to the National Fire Protection Association, Batterymarch

Park, Quincy, MA 02269. When writing refer to NFPA No. 96.

3. All models require a 6" (152 mm) clearance at both sides and

rear adjacent to combustible construction.

4. All models require a 16" (407 mm) minimum clearance to

adjacent open top burner units.

5. This appliance is manufactured for commercial installation

only and is not intended for home use.

SERVICE CONNECTIONS:

P1

1

/

2

" (13 mm) rear gas connection (single units).