– 10 –
F-25114 Rev.A (07-03)
GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS
FILTER VALVE AND DISCARD
VALVE SWITCHES
WARNING:
DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES. THERE MAY
BE MULTIPLE CIRCUITS. BE SURE
ALL CIRCUITS ARE DISCONNECTED.
1. Open the door to the fryer section being serviced.
2. Remove burners closest to the switch being serviced
(if applicable) as outlined under “GAS BURNERS”.
3. Disconnect lead wire connector (2 pin) from the
appropriate switch.
4. Remove switch mounting screws.
5. Reverse procedure to install and check for
proper operation.
NOTE:
Switches are not adjustable.
GAS BURNERS
WARNING:
DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES. THERE MAY
BE MULTIPLE CIRCUITS. BE SURE
ALL CIRCUITS ARE DISCONNECTED.
WARNING:
SHUT OFF THE GAS BEFORE SERVICING
THE UNIT.
1. Open the door to the fryer section being serviced.
2. Remove gas burner shipping ties (if installed).
3. Lift gas burner up and tilt the top of burner toward
fryer until it clears the gas orifice at the bottom.
NOTE: The burners mount to the fryers’ burner mounting
bracket by shoulder bolts that rest in the keyway slot.
4. Reverse procedure to install.
Содержание GRC35
Страница 29: ... 29 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION COMPONENT LOCATION ...
Страница 30: ... 30 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION POWER SUPPLY BOX ...
Страница 37: ... 37 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION ...
Страница 39: ... 39 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION ...
Страница 40: ... 40 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION Junction Box Kleenscreen Filtering System ...
Страница 41: ... 41 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION Frymate Dump Station ...
Страница 48: ... 48 F 25114 Rev A 07 03 NOTES GR SERIES GAS FRYERS ...