Vulcan-Hart COUNTER CONVECTION STEAMERS 52396 Скачать руководство пользователя страница 3

3

ANCHORING STEAMER (Without Legs)

1.

Place steamer in the desired location on the
leveled counter top and mark four corners.
Remove the steamer and drill 

1

/

2

" holes as

indicated in Fig. 1.

2.

Apply a bead of RTV or other equivalent sealant
around the bottom perimeter edge of the steamer.
If anchoring the steamer, this bottom seal is
necessary to meet NSF requirements.

3.

Set steamer on counter and bolt down securely
with 

3

/

8

 - 16  bolts (not supplied).

STACKING KIT

Follow instructions in the stacking kit when installing
stacked convection steamers.

24"

20"

2"

27 1/2"

23 1/2"  

Drill 1/2" holes through 
counter top

Mark 4 corners on 
counter top

PL-50819

Fig. 1

ELECTRICAL CONNECTION

WARNING

:  ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE

PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING

: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE

DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.

The wiring diagram is located on the right side panel as you face the steamer.

ELECTRICAL DATA

Total 

KW

  Volts / Hz / Ph

Kilowatts Per Phase

Rated Amps

Circuit Size

(Amps)

Fuse Size or 

Circuit Breaker Size *

(Amps)

90°C Copper

Wire Size

3 Phase  

Amps Per Line Wire

1 Phase

Amps

L1 - L2

L2 - L3

L1 - L3

L1

L2

L3

7.5

208 / 60 / 1

36

50

50

8

7.5

240 / 60 / 1

31

45

45

8

7.5

208 / 60 / 3

2.5

2.5

2.5

21

21

21

30

30

10

7.5

240 / 60 / 3

2.5

2.5

2.5

18

18

18

25

25

14

7.5

480 / 60 / 3

2.5

2.5

2.5

9

9

9

15

15

16

10

208 / 60 / 1

48

70

70

8

10

240 / 60 / 1

42

60

60

8

10

208 / 60 / 3

3.3

3.3

3.3

28

28

28

40

40

10

10

240 / 60 / 3

3.3

3.3

3.3

24

24

24

35

35

10

10

480 / 60 / 3

3.3

3.3

3.3

12

12

12

15

15

16

15

208 / 60 / 1

72

100

100

6

15

240 / 60 / 1

63

90

90

6

15

208 / 60 / 3

5

5

5

42

42

42

60

60

8

15

240 / 60 / 3

5

5

5

36

36

36

50

50

8

15

480 / 60 / 3

5

5

5

18

18

18

25

25

14

* Dual Element Time-Delay Fuse or

Inverse Time Circuit Breaker

  Circuit Size (Minimum) & Fuse / Circuit Breaker Size (Maximum) compiled in accordance with the National Electrical Code (ANSI/NFPA 70), 1993 Edition.

Содержание COUNTER CONVECTION STEAMERS 52396

Страница 1: ...PANY P O BOX 696 LOUISVILLE KY 40201 0696 TEL 502 778 2791 FORM 30896 10 94 INSTALLATION OPERATION MANUAL FOR ELECTRIC COUNTER CONVECTION STEAMERS MODELS VSX3 VSX4 VSX5 ML S 52396 52397 52398 52399 MO...

Страница 2: ...erify that the electrical service agrees with the specifications on the machine data plate which is located on the left side panel LOCATION Allow space for plumbing and electrical connections Minimum...

Страница 3: ...TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT The wiring diagram is located on the right side panel as you face the steamer ELECTRICAL DATA Total KW Volts Hz Ph Kilowatts...

Страница 4: ...t should be consulted before installing any steam generating equipment Untreated water contains scale producing minerals which can precipitate onto the surfaces in the boiler Due to the temperatures i...

Страница 5: ...ial timer to 5 minutes With door open observe that no steam is entering the compartment and the COOKING light is not lit 4 Close compartment door The COOKING light is lit and steam should be heard ent...

Страница 6: ...s have accumulated in the steam generator and that a DELIME procedure should be performed at the next convenient opportunity See Maintenance page 12 PREHEAT Turn the main power switch ON When the READ...

Страница 7: ...erve their juice or retain broth Canned foods can be heated in their opened cans cans placed in 12 x 20 solid pans or the contents may be poured into solid pans DO NOT place unopened cans in the steam...

Страница 8: ...inse with warm clear water and wipe with a dry cloth CAUTION Do not allow the door gasket to come in contact with food oils petroleum solvents or lubricants Keep the cooking compartment drain working...

Страница 9: ...esh pre blanched or frozen and degree of doneness desired COOK IN SOLID PANS PRODUCT TIME minutes WEIGHT PER PAN Eggs Scrambled 10 12 8 Doz Rice Long Grain 25 2 Lb Cover with 4 cups water per pound Pa...

Страница 10: ...Lb Scallops Fresh 4 3 Lb Scrod Fillets Fresh 3 5 4 Lb Eggs Hard Cooked 15 4 Doz Soft Cooked 9 10 4 Doz Soft Yoke for Caesar Salad 6 8 4 Doz Chicken Breasts Legs Thighs 20 15 Lb Turkey Frozen Breasts...

Страница 11: ...Fresh 7 8 5 Lb Celery 1 Diagonal Cut 7 5 Lb Corn Yellow Whole Kernal Frozen 5 5 Lb Cobbettes Frozen 8 27 Ears 16 18 80 Ears Corn On Cob Fresh 10 12 18 Ears 16 18 54 Ears Peas Green 6 5 Lb Potatoes Wh...

Страница 12: ...e the steam generator COLD WATER CONDENSER The steamer is equipped with a cold water condenser in the rear of the cooking chamber which helps to condense the steam prior to discharge into the drain Th...

Отзывы: