LIFT SPRING ADJUSTMENT
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
Check spring tension:
A.
Raise heating elements to full up position.
Elements should remain in place.
B.
Lower heating elements to full down
position. Elements should remain in place.
C.
If elements remain in place as described,
then no adjustment is necessary. If
elements do not remain in place, continue
with procedure for adjustment.
2.
Adjust spring tension:
Take care when removing rear electrical
cover as it can fall free and pull loose or damage wires.
A.
Remove ELECTRICAL COVER .
B.
Remove screws and back panel.
C.
Loosen stop nut on all eye bolts.
D.
Adjust eye bolt mounting nuts as necessary,
but equally on all springs to achieve the best
spring tension to hold elements in place.
E.
Repeat Step 1 as necessay until spring
tension is acceptable.
F.
Tighten stop nut on all eye bolts.
3.
Reinstall back panel and electrical cover.
CEF40/75 FRYER - SERVICE PROCEDURES AND ADJUSTMENTS
F45657 (0517)
Page 16 of 25