GAS PRESSURE REGULATOR INSTALLATION 

Gas regulator pressure is preset at 5” Water Column (W.C.) for natural gas, and 10” W.C. 
for propane gas. Minor adjustments may be required based on site specific gas pressure. 

Install the regulator as close to the broiler on the gas supply line as possible. Make sure 
that the arrow on the underside of the regulator is oriented in the direction of gas flow to 
the broiler (Fig. 2) and the regulator is positioned with the vent plug and adjustment 
screw upright (Fig. 3). 

 

Fig. 2 

 

Fig. 3 

The minimum supply pressure (upstream of the regulator) should be 7-9” W.C. for natural 
gas and 11-12” W.C. for propane gas. At no time should the charbroiler be connected to 
supply pressure greater than ½ psig (3.45 kPa) or 14” W.C. 

CASTER EQUIPPED CHARBROILERS 

Charbroilers mounted on stands with casters must use a flexible connector (not supplied) 
that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 
• CSA 6.16 and a quick-disconnect device that complies with the Standard for Quick-
Disconnect Devices for use With Gas Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate 
means must be provided to limit movement of the broiler without depending on the 
connector and the quick-disconnect device or its associated piping to limit broiler 
movement. Attach the restraining device at the rear of the charbroiler. If disconnection of 
the restraint is necessary, turn off the gas supply before disconnection. Reconnect the 
restraint prior to turning the gas supply on and return the charbroiler to its installation 
position. 

Note: If the Charbroiler is installed on casters and is moved for any reason, it is 
recommended that it be re-leveled (see LEVELING). 

 

OPERATION 

WARNING

:  THE CHARBROILER AND ITS PARTS ARE HOT.  USE CARE WHEN OPERATING, 

CLEANING, OR SERVICING THE CHARBROILER. 
 
 
 
 

Содержание ACB20

Страница 1: ...8 INSTALLATION OPERATION MANUAL FOR Achiever Charbroilers MODELS MLS VACB20 ML 135285 VACB25 ML 710543 VACB36 ML 710544 VACB47 ML 710545 VACB60 ML 710546 VACB72 ML 135286 www vulcanhart com MODELS MLS ACB20 ML 135285 ACB25 ML 710543 ACB36 ML 710544 ACB47 ML 710545 ACB60 ML 710546 ACB72 ML 135286 www wolfrange com VACB47 ...

Страница 2: ...PORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE I...

Страница 3: ...00 INSTALLATION UNPACKING Immediately after unpacking check for possible shipping damage If the broiler is found to be damaged save the packaging material and contact the carrier within 15 days of delivery Before installing verify that the type of gas natural or propane and the clearance dimensions see page 4 agree with the specifications on the rating plate which is located on the upper front cor...

Страница 4: ...pped with a damper or with a power means of exhaust shall comply with 248 CMR 3 NFPA Standard 96 Vapor Removal from Cooking Equipment latest edition available from the National Fire Protection Association Batterymarch Park Quincy MA 02269 In Canada 1 Local codes 2 CAN CSA B149 1 Natural Gas Installation latest edition 3 CAN CSA B149 2 Propane Installation Code latest edition available from the Can...

Страница 5: ...the equivalent of iron pipe A pressure regulator is supplied and must be installed outside of the broiler when making the gas supply connection Standard orifices are set for 5 WC Water Column for Natural Gas 10 WC Water Column for Propane Use the 1 8 pipe tap on the burner manifold for checking pressure Make sure the gas piping is clean and free of obstructions dirt and piping compound An adequate...

Страница 6: ...th casters must use a flexible connector not supplied that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for use With Gas Fuel ANSI Z21 41 CSA 6 9 In addition adequate means must be provided to limit movement of the broiler without depending on the connector and th...

Страница 7: ...o keep the grates clean Do not allow debris to accumulate on the grates Turn flame to low setting during slack periods to conserve energy The charbroiler is a free vented appliance All products of combustion and the heat generated by the burners pass through the grates When meat is placed on the grates this blocks the venting and causes a temperature build up The charbroiler operates most efficien...

Страница 8: ...s shown For correct operation ensure that the flat Burner Deflector assemblies remain on the right and left CLEANING Scrape top grates thoroughly so grease flows to trough and grease drawer uninhibited This prevents flare ups Top grates may be immersed in strong commercial cleaning compound overnight In the morning rinse with hot water to remove any residues of cleaning compound Stainless steel su...

Страница 9: ... 9 ...

Страница 10: ...en mounted on a stand with standard legs and properly leveled the cooking surface should be approximately 36 from the floor GRATES The charbroiler has a variety of optional grate accessories Refer to your current catalog for pricing and availability CONDIMENT RAIL Refer to the installation instructions provided with the condiment rail kit CAST DIAMOND GRATE Thicker markings More caramelizing Low t...

Отзывы: