LEVELING 

It is important that the charbroiler is level front to back and left to right.  Areas of uneven 
heat distribution will occur on an unleveled unit.  The charbroiler is equipped with 
adjustable legs.  Turn the feet at the bottom of the legs to adjust to level.  The unit should 
be rechecked for level anytime it has been moved. 

 

VENTILATION HOOD 

The broiler should be installed under a suitable ventilation hood. For safe operation and 
proper ventilation, keep the space between the charbroiler and vent hood free from any 
obstructions. 

GAS CONNECTION 

The data plate on the lower right side of the charbroiler indicates the type of gas your unit 
is equipped to burn.  DO NOT connect to any other gas type. 

CAUTION:  All gas supply connections and any pipe joint compound must be 
resistant to the action of propane. 

Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting 
the line to the unit. 

Codes require that a gas shut-off valve be installed in the gas line ahead of the 
charbroiler.  The gas supply line must be at least the equivalent of ¾” iron pipe.     

A pressure regulator is supplied and must be installed outside of the broiler when making 
the gas supply connection.  Standard orifices are set for 5"WC (Water Column) for 
Natural Gas — 10"WC (Water Column) for Propane.  Use the 

1

/

8

” pipe tap on the burner 

manifold for checking pressure.  Make sure the gas piping is clean and free of 
obstructions, dirt, and piping compound. 

An adequate gas supply is necessary.  Undersized or low pressure lines will restrict the 
volume of gas required for satisfactory performance.  A minimum supply pressure of 7" 
W.C. for natural gas and 11" W.C. for propane gas is recommended.  With all units 
operating simultaneously, the manifold pressure on all units should not show any 
appreciable drop.   

When testing the gas supply piping system, if test pressures exceed ½ psig (3.45 kPa), 
the charbroiler and its individual shutoff valve must be disconnected from the gas supply 
piping system.  When test pressures are ½ psig (3.45 kPa) or less, the charbroiler must 
be isolated from the gas supply piping system by closing its individual manual shut-off 
valve during any pressure testing of the system. 

WARNING

:  PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR 

LEAKS.  USE SOAP AND WATER SOLUTION.  DO NOT USE AN OPEN FLAME. 

 

 

Содержание ACB20

Страница 1: ...8 INSTALLATION OPERATION MANUAL FOR Achiever Charbroilers MODELS MLS VACB20 ML 135285 VACB25 ML 710543 VACB36 ML 710544 VACB47 ML 710545 VACB60 ML 710546 VACB72 ML 135286 www vulcanhart com MODELS MLS ACB20 ML 135285 ACB25 ML 710543 ACB36 ML 710544 ACB47 ML 710545 ACB60 ML 710546 ACB72 ML 135286 www wolfrange com VACB47 ...

Страница 2: ...PORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE I...

Страница 3: ...00 INSTALLATION UNPACKING Immediately after unpacking check for possible shipping damage If the broiler is found to be damaged save the packaging material and contact the carrier within 15 days of delivery Before installing verify that the type of gas natural or propane and the clearance dimensions see page 4 agree with the specifications on the rating plate which is located on the upper front cor...

Страница 4: ...pped with a damper or with a power means of exhaust shall comply with 248 CMR 3 NFPA Standard 96 Vapor Removal from Cooking Equipment latest edition available from the National Fire Protection Association Batterymarch Park Quincy MA 02269 In Canada 1 Local codes 2 CAN CSA B149 1 Natural Gas Installation latest edition 3 CAN CSA B149 2 Propane Installation Code latest edition available from the Can...

Страница 5: ...the equivalent of iron pipe A pressure regulator is supplied and must be installed outside of the broiler when making the gas supply connection Standard orifices are set for 5 WC Water Column for Natural Gas 10 WC Water Column for Propane Use the 1 8 pipe tap on the burner manifold for checking pressure Make sure the gas piping is clean and free of obstructions dirt and piping compound An adequate...

Страница 6: ...th casters must use a flexible connector not supplied that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for use With Gas Fuel ANSI Z21 41 CSA 6 9 In addition adequate means must be provided to limit movement of the broiler without depending on the connector and th...

Страница 7: ...o keep the grates clean Do not allow debris to accumulate on the grates Turn flame to low setting during slack periods to conserve energy The charbroiler is a free vented appliance All products of combustion and the heat generated by the burners pass through the grates When meat is placed on the grates this blocks the venting and causes a temperature build up The charbroiler operates most efficien...

Страница 8: ...s shown For correct operation ensure that the flat Burner Deflector assemblies remain on the right and left CLEANING Scrape top grates thoroughly so grease flows to trough and grease drawer uninhibited This prevents flare ups Top grates may be immersed in strong commercial cleaning compound overnight In the morning rinse with hot water to remove any residues of cleaning compound Stainless steel su...

Страница 9: ... 9 ...

Страница 10: ...en mounted on a stand with standard legs and properly leveled the cooking surface should be approximately 36 from the floor GRATES The charbroiler has a variety of optional grate accessories Refer to your current catalog for pricing and availability CONDIMENT RAIL Refer to the installation instructions provided with the condiment rail kit CAST DIAMOND GRATE Thicker markings More caramelizing Low t...

Отзывы: