REMOVAL AND REPLACEMENT OF PARTS
3.
Remove screws securing thermostat mounting
bracket to frame.
4.
Pull capillary tube out from underneath griddle
plate.
5.
Transfer fittings from old thermostat to new
thermostat. Use thread sealant.
6.
Transfer thermostat mounting bracket to new
thermostat.
7.
Remove insulator sleeve from old capillary tube
and install on new thermostat.
8.
Secure end of insulator sleeve to thick end of
capillary tube with metal tape as shown.
9.
Slide capillary tube all the way into slot
underneath griddle plate until it is fully seated.
10. Carefully insert orifice into burner and secure
thermostat mounting bracket to frame.
11. Inlet to burner must be straight. Adjust thread
on orifice and/or extension to close gap
between orifice and burner to 1/16".
12. Continue to install in reverse order.
F25383 (510)