Printed On Recycled Paper
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791
QUOTE & ORDER FAX: 1-800-444-0602
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
F-32384 (10-03)
MODEL 2T2036D
TWO 24 QUART
2
/
3
JACKETED TILTING
DIRECT STEAM KETTLES ON CABINET BASE
SERVICE CONNECTIONS:
A
Steam Supply Connection:
3
/
4
".
B
Drain: Condenser box, compartment and boiler,1
1
/
4
" NPT. (Provide an
open air gap type drain within 12" of condenser box and for best results
at a distance so that steam vapors will not enter the steamer from
underneath the control area. Do not connect solidly to any drain
connection.)
C
Water Supply Connection for Kettle Filler Faucet:
1
/
4
" NPT.
NOTE:
• Dimensions which locate the above connections have a tolerance of +
or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other specific
code requirements is the responsibility of the owner and installer. It is
the responsibility of the owner and installer to comply with local codes.
• Plastic drains are not recommended due to inherent limited tempera-
tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge water
temperature to be that of the condensate temperature of 140°F or less.
• This appliance is manufactured for commercial installation only and is
not intended for home use.
DIRECT STEAM DATA:
Steam supply to the kettle must:
1. Maintain a steady 13 psi flow under operating conditions.
2. Have a minimum flow rate of 42 lbs. (1.2 BHP)/hr., dry steam.
3. Be adequately trapped to provide dry steam. (See ball float trap.)
EQUIPMENT CLEARANCE:
Rear: 2"
Right: 0"
Left: 0"
CAPACITIES (in 4 oz. servings):
24 quarts / 6 gallons / 22.5 liters - 192 servings.