HOT WATER DELIVERY 

This water heater can deliver water at temperatures which can cause scalding. 
 
It is necessary and we recommend that a temperature limiting device be fitted between the water heater and 
the  hot  water outlets in any  ablution  and public areas such as a bathroom, ensuite  or public amenities,  to 
reduce the risk of scalding. The installing plumber may have a legal obligation to ensure the installation of 
this  water  heater  meets  the  delivery  water  temperature  requirements  of  AS/NZS 3500.4  so  that  scalding 
water temperatures are not delivered to a bathroom, ensuite or other ablution or public area. 
 
The temperature limiting device used with a continuous flow gas water heater should have: 

 

a specified „minimum temperature differential‟ between the hot water inlet and the tempered water outlet 
of no greater than 10°C, and 

 

a  specified  „maximum  permitted  pressure  variation‟  in  the  supply  between  the  hot  water  inlet  and  the 
cold water inlet of no less than 15%. 

Refer to the specifications of the temperature limiting device. 
 
The  temperature  limiting  device  used  with  an  in-series  gas  booster    as  part  of  a  solar  water  heater 
installation must have the additional capability of receiving a hot water supply temperature of up to 99°C if 
the solar water heater does not have an over temperature protection system to limit the water to no greater 
than 90°C. 
 

 

Warning:

 Temperature controllers 

must not

 be fitted to this water heater as part of a solar water heater 

system because water at a temperature much higher than the controller setting can be delivered. 
 
Where a temperature limiting device is installed adjacent to the  in-series gas booster, the cold water line to 
the  temperature  limiting  device  can  be  branched  off  the  cold  water  line  either  before  or  after  the  isolation 
valve and pressure limiting valve to the solar storage tank, but it 

MUST BE

 before the non return valve prior 

to an open circuit direct system. The cold water line to the temperature limiting device can be branched off 
the cold water line  either before or after the non return valve prior to a closed circuit indirect system. If an 
expansion  control  valve  is  required,  it  must  always  be  installed  after  the  non  return  valve  and  be  the  last 
valve prior to the solar storage tank. 
 

 

Warning:

 A non return valve 

MUST BE

 installed on the cold water line to the solar storage tank 

AFTER

 

the  cold  water  branch  to  a  temperature  limiting  device  prior  to  an  open  circuit  direct  system.  Due  to  the 
higher water temperatures generated under certain conditions in the solar collectors of an open circuit direct 
solar  water  heater,  an  additional  effective  back-flow  prevention  device  also  should  be  used  as  an  extra 
safeguard. Valve manufacturer RMC recommends Dual Check Valve model N7150, as being suitable for this 
application. 
 
If a combination isolation valve and non return valve (duo or trio valve) is installed on the cold water line to 
an open circuit direct solar water heater and the cold water line to the temperature limiting device branches 
off after this valve, then a second non return valve must be installed between the cold water branch and the 
solar  storage  tank.  Due  to  the  higher  water  temperatures  generated  under  certain  conditions  in  the  solar 
collectors  of  an  open  circuit  direct  pumped  solar  water  heater,  an  effective  back-flow  prevention  device 
should  be  used  as  the  second  non  return  valve  as  an  extra  safeguard.  Valve  manufacturer  RMC 
recommends Dual Check Valve model N7150, as being suitable for this application. 
 
If a pressure limiting valve is installed on the cold water line to the solar water heater and the cold water line 
to  a  temperature  limiting  device  branches  off  before  this  valve  or  from  another  cold  water  line  in  the 
premises,  then  a  pressure  limiting  valve  of  an  equal  pressure  setting  may  be  required  prior  to  the 
temperature limiting device. 
 

Содержание 244 027

Страница 1: ...ter heater must be installed and serviced by a qualified person Please leave this guide with the householder Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater 244 series 027...

Страница 2: ...f Rheem Australia Pty Ltd Trademark of Rheem Australia Pty Ltd Note Every care has been taken to ensure accuracy in preparation of this publication No liability can be accepted for any consequences wh...

Страница 3: ...er pages are intended for the installer but may be of interest About Your Water Heater 4 Water Supplies 10 Save A Service Call 11 Installation Water Heater 14 Connections Plumbing 22 Connections Elect...

Страница 4: ...outlet temperature setting as the water passes through the water heater The heat produced by the burner is transferred to the water through the heat exchanger The water is heated to a constant temper...

Страница 5: ...l outlet Take care not to touch the power plug with wet hands SAFETY This water heater is supplied with temperature sensors a FlameSafe protection system and a pressure relief valve These devices must...

Страница 6: ...ion of the water heater and also damage components MINOR SIX MONTH MAINTENANCE It is recommended minor maintenance be performed every six months by the dwelling occupant The minor maintenance includes...

Страница 7: ...at the solar heated water inlet and hot water outlet of the water heater if the water heater has been drained Open all of the hot taps in the house don t forget the shower Open the cold water isolati...

Страница 8: ...risk of freezing then it is necessary to drain the water heater refer to Draining the Water Heater on page 8 Pipe work to and from the water heater must be adequately insulated to prevent freezing Th...

Страница 9: ...from the Victorian Plumbing Industry Commission This water heater must be installed by a licensed person as required by the Victorian Building Act 1993 Only a licensed person will give you a Complianc...

Страница 10: ...mation should be sought from the supplier or it should be tested to ensure the water supply meets the requirements given in these guidelines for the Vulcan warranty to apply SATURATION INDEX The satur...

Страница 11: ...appliance Has the gas line been purged of air after installation Refer to your plumber NO WATER FROM THE HOT TAP No flow of water from the hot tap may indicate a restriction in or failure of the cold...

Страница 12: ...glass Ensure the glass on your solar collectors is free of dust salt spray or any other matter which may reduce the effectiveness of the solar collectors If the collector glass becomes dirty hose down...

Страница 13: ...e If an error code appears Close the hot tap and switch off the electrical supply to the water heater Check the gas isolation valve at the gas inlet to the water heater is fully open Wait 5 minutes th...

Страница 14: ...uitable for installation as an in series gas booster to a solar water heater For information relating to the function and operation of the solar water heater refer to the Owner s Guide and Installatio...

Страница 15: ...ured along the wall behind the water heater At least 300 mm between the top of the flue terminal and the eaves At least 500 mm between the flue terminal and the edge of any opening into the building s...

Страница 16: ...g wind chill factor The solar preheat line to the water heater must be insulated with suitable thickness insulation if freezing conditions are likely to occur The insulation must be fitted to the unde...

Страница 17: ...g valve to the solar storage tank but it MUST BE before the non return valve prior to an open circuit direct system The cold water line to the temperature limiting device can be branched off the cold...

Страница 18: ...allation Two Temperature Zones Using a Temperature Limiting Device LEGEND In series Gas Booster as part of a Closed Circuit Indirect Solar Water Heater Installation Two Temperature Zones Using a Tempe...

Страница 19: ...on of the return line connection on the water supply line to the water heater then either water will be supplied to the cold water inlet of the temperature limiting device at a temperature exceeding t...

Страница 20: ...s Hourly Gas Consumption MJ Min Gas Pressure kPa Test Point Gas Pressure kPa Max Gas Pressure kPa minimum maximum Model 027 027 027 027 027 Natural 205 1 13 0 193 0 905 3 50 Propane 205 2 75 0 277 1 4...

Страница 21: ...INSTALLATION WATER HEATER 21 TYPICAL INSTALLATION OUTDOOR LOCATION TYPICAL INSTALLATION ELECTRONIC CONTINUOUS FLOW GAS BOOSTER WATER HEATER FOR SOLAR PREHEAT WATER HEATER...

Страница 22: ...efer also to Hot Water Delivery on page 17 and to Mains Water Supply on page 16 A disconnection union must always be provided at the cold water solar preheat inlet and hot water outlet on the water he...

Страница 23: ...tions on both the solar storage tank and the in series gas booster A full flow isolation valve must be installed on the water line to the in series gas booster GAS INLET The gas connection is made at...

Страница 24: ...red The water heater is supplied with a 1 8 metre lead and plug and requires a weatherproof 240 V 50 Hz general purpose outlet GPO to be located within 1 2 metres of the installation The GPO must be c...

Страница 25: ...ated in the water heater is not adjustable To complete the installation it is necessary to check the gas supply pressure at the inlet to the water heater refer to Gas Inlet Pressure on page 25 the min...

Страница 26: ...ensure the burners are fully ignited It may be necessary to open a second tap 8 Turn on all other gas burning appliances in the house which are on the same gas supply 9 Observe the gas pressure readi...

Страница 27: ...et to the water heater 7 Open the gas isolation valve fully at the gas inlet to the water heater if not already open 8 Open a hot tap slowly until the burners ignite 9 Press and hold down the MIN butt...

Страница 28: ...Code If an error code does appear on the LED display during the commissioning process it will be necessary to clear the error in order to complete the installation To clear an error code switch off th...

Страница 29: ...n the LED display is the desired preset outlet temperature setting then proceed to step 7 as no further adjustment is necessary 6 Press the MAX button to increase or the MIN button to decrease the pre...

Страница 30: ...eater Damage caused by freezing due to the unavailability of power at the water heater is not covered by the Vulcan warranty refer to Terms of the Vulcan Warranty on page 31 If the power has been swit...

Страница 31: ...g or removing cupboards doors or walls and the cost of any special equipment to bring the water heater to floor or ground level or to a serviceable position is not covered by this warranty 2 5 This wa...

Страница 32: ...rranty period 4 2 You are not entitled to make a claim under this warranty if your water heater a Does not have its original serial numbers or rating labels b Is not installed in Australia 5 HOW TO MA...

Отзывы: