background image

Printed On Recycled Paper

VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028

502-778-2791

QUOTE & ORDER FAX: 1-800-444-0602

NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.

MODEL 1T2018D

24 QUART TILTING STEAM KETTLE ON CABINET BASE

DIRECT STEAM DATA:

Steam supply to the kettles must:

1. Maintain a steady 13 psi flow under operating conditions.

2. Have a minimum flow rate of 21 lbs. (.6 BHP)/hr., dry steam.

3. Be adequately trapped to provide dry steam. (See ball float trap).

EQUIPMENT CLEARANCE:

Rear: 2"

Right: 0"

Left: 0"

CAPACITIES (in 4 oz. servings):

24 quarts / 6 gallons / 22.5 liters - 192 servings.

SERVICE CONNECTIONS:

S

Steam Supply Connection: 

3

/

4

" NPT.

D

Drain:  Condenser box, compartment and boiler, 2" NPT. (Provide an
open air gap type drain within 12" of condenser box and for best
results at a distance so that steam vapors will not enter the steamer
from underneath the control area. Do not connect solidly to any drain
connection.)

Water Supply Connection for kettle filler faucet: 

1

/

4

" NPT.

NOTE:

• Dimensions which locate the above connections have a tolerance of

+ or -3" (+ or -75 mm).

• Installation of backflow preventers, vacuum breakers and other

specific code requirements is the responsibility of the owner and
installer. It is the responsibility of the owner and installer to comply with
local codes.

• Plastic drains are not recommended due to inherent limited tempera-

tures of the plastic. Boiler purge temperatures may exceed 180

°

F.

The installer may be required to provide means to reduce boiler purge
water temperature to be that of the condensate temperature of 140

°

F

or less.

• This appliance is manufactured for commercial installation only and

is not intended for home use.

F-31680 (2-06)

Отзывы: