ventilation, make sure ventilation openings in inverter are not
obstructed. Then switch the ON/OFF switch back to ON.
-
Short circuit / wiring error/ very high power load:
The fault indicator(s) also indicates that the power inverter has
shut itself down because its output circuit has been short
circuited or drastically overloaded.
Switch the ON/OFF switch to OFF. Check AC wiring for short
circuit or improper connection, correct the fault condition; or
remove load. Then switch the ON/OFF switch back to ON.
5.2.
Empty battery indicator
The indicator “Empty” indicates that the power inverter has shut
itself down because of low input voltage. This maybe because
the battery is almost empty or connections are loose or rusted.
Switch the ON/OFF switch to OFF, recharge the battery, check
connections, and then switch the ON/OFF switch back to ON.
6.
Green Power
This status features automatic load-sensing, which allows the
inverter to wait in Standby mode until an AC load is switched ON.
When an AC load appears, the inverter will immediately start.
This feature conserves valuable battery energy as the inverter
uses only about 10% of normal power when in standby mode.