background image

 

S400VA / S1000VA / S1500VA 

 

 

www.vuphong.vn

|

www.vuphong.asia

 

ventilation,  make sure  ventilation  openings  in  inverter  are  not 
obstructed. Then switch the ON/OFF switch back to ON. 

-

 

Short circuit / wiring error/ very high power load: 

The fault indicator(s) also indicates that the power inverter has 
shut  itself  down  because  its  output  circuit  has  been  short 
circuited or drastically overloaded. 

Switch  the  ON/OFF  switch  to  OFF.  Check  AC  wiring  for  short 
circuit  or  improper  connection,  correct  the  fault  condition;  or 
remove load. Then switch the ON/OFF switch back to ON. 

5.2.

 

Empty battery indicator 

The indicator “Empty” indicates that the power inverter has shut 
itself down because of low input voltage. This maybe because 
the battery is almost empty or connections are loose or rusted.  

Switch the ON/OFF switch to OFF, recharge the battery, check 
connections, and then switch the ON/OFF switch back to ON. 

6.

 

Green Power 

This  status  features  automatic  load-sensing,  which  allows  the 
inverter to wait in Standby mode until an AC load is switched ON. 
When an AC load appears, the inverter will immediately start. 

This feature conserves valuable battery energy as the inverter 
uses only about 10% of normal power when in standby mode. 

Содержание S400VA

Страница 1: ...de range of applications It will operate most televisions fans lamps personal computers small appliances and tools The inverter must have a greater power rating than the load it provides power to To g...

Страница 2: ...s Battery Deep Discharge Low Voltage Disconnect Reconnect AC Short Circuit Over Load Reverse DC Polarity No Load Power Consumption 2W in Green Power status 6W 4W in Green Power status Cooling Method N...

Страница 3: ...w Cable shoe Connect to 12V battery Red is positive Black Blue is negative 3 2 Front side a AC outlets Connect to 220V loads b Green Power switch S400VA S1500VA Energy saving enable Turn the switch ON...

Страница 4: ...loose connection red 4 Installation 4 1 Where to install The power inverter should be installed in a location that meets the following requirements a Dry Do not allow water to drip or splash on the i...

Страница 5: ...the negative terminal of the battery Tighten the screw to clamp the wires securely Caution Loose connections result in excessive voltage drop and may cause overheated wires and melted insulation Caut...

Страница 6: ...loads If you are operating several loads from the power inverter turn them on separately after the inverter has been turned on This will ensure that the power inverter does not have to deliver the sta...

Страница 7: ...move load Then switch the ON OFF switch back to ON 5 2 Empty battery indicator The indicator Empty indicates that the power inverter has shut itself down because of low input voltage This maybe becaus...

Страница 8: ...en though their rated current draw is within the power inverter 7 2 Input voltage The power inverter will shut down if the input voltage drops below 10 5V This protects your battery from being overly...

Отзывы: