www.vtiinstruments.com
APPENDIX B
51
of ½ decimation filter stages. While the
ClockFrequency
is global, the
SampleRate
and
Span
value
can be different in each channel. The value must be the one derived from a global
ClockFrequency
.
Span
The
Span
is the nominal frequency range of the acquired signal. The value of
Span
is determined
by the decimation filter’s cutoff frequency. In non-oversample mode, the
Span
=
SampleRate
/2.56
in. When
Oversample
is true, the Span =
SampleRate
/5.12.
RecordSize
The
RecordSize
specifies the number of data samples read back from the instrument at a time. The
total number of data samples captured for each trigger is equal to the product of
RecordSize
and the
Measurement.NumRecordsPerTrigger
property -- that is,
NumRecordsPerTrigger
records are
captured, and each is of size
RecordSize
. Figure 4-12 shows the case where
NumRecordsPerTrigger
= 4. As a special case, when
NumRecordsPerTrigger
is set to 0, an infinite number of data records
are returned in
RecordSize
sample chunks after a trigger event until the measurement is aborted.
Trigger Level
Trigger
Trigger
Record
Record
Record
Record
Record
Record
Record
Record
Figure 4-13: Record Size and NumRecordsPerTrigger
With EMX-4250/4350/4380, the minimum
RecordSize
is 1 and the maximum power of 2
RecordSize
is 32768. Since each data packet transferred from the instrument to the host contains
one data record from each ADC channel, in general, the user can achieve higher data transfer using
a larger
RecordSize
value due to reduced overhead, but this affects the data update interval, as the
amount of time to acquire one data record is: T =
RecordSize
/
SampleRate
.
Oversample
When the
Oversample
is set to true, the data is twice oversampled than Nyquist sample rate. The
SampleRate
becomes 5.12 times of
Span
. The
Oversample
mode is currently not supported.
Multipass
When the
Multipass
property is set to true, the data record contains data samples from multiple
½ decimation spans below the current decimation span specified by
Span
property. The
RecordSize
/2 samples is at
Span, RecordSize
/4 samples is at
Span
/2,
RecordSize
/8 samples is
Span
/4, etc., until it reaches less than 1 sample or the lowest decimation stage.
Multipass
is currently
not supported.
Содержание EMX-4016B
Страница 6: ......
Страница 7: ...www vtiinstruments com Introduction 7 ...
Страница 83: ...www vtiinstruments com APPENDIX B 83 Figure 4 429 EMX 4016B Break Out Box Figure 4 30 EMX 4016M Break Out Box ...
Страница 84: ...VTI Instruments Corp APPENDIX B 84 Figure 4 31 EMX4016B Outline Drawing Figure 4 32 Drawing Represent ...
Страница 116: ......