www.vtiinstruments.com
EX1200A Series Preparation for Use
55
An executable for installing JRE is available on the
VTI Instruments Corp. Drivers and Product
Manuals
CD provided with the EX1200A. If JRE is currently installed on the host PC, the
software installation instruction for this software can be skipped.
The
LXI Discovery Tool
searches for all LAN-based VTI devices on the network and can be
. This utility leverages
use version v2.0.2 and later for proper operation of the LXI Discovery Tool..
Java Installation
Java Runtime Environment (JRE) is required to access the SFP page of the EX1200A. Prior to
installing JRE, ensure that all IE sessions have been closed. To install JRE, insert the
VTI Instruments Corp. Drivers and Product Manuals
CD into the host PCs CD-ROM and, using
Windows Explorer, navigate to the
<CD-ROM Drive>:\EX Platforms Requisites
directory. Next,
run the
JRESetup.exe
program. Once installation begins, simply follow the on-screen
instructions.
D
RIVER
I
NSTALLATION
To monitor and/or control the EX1200A
’s instrume
nts programmatically (via a user generated
program or through tools such as HP
VEE, National Instrument’s Switch Executive, etc.), two
additional components must be installed: the IVI Shared Components library and the provided
VTI Instruments driver. Follow these steps:
IVI Shared Components Installation
If this component was installed during a previous LXI instrument installation, please proceed to
Switch Instrument Driver Installation
. First, close all other open programs, leaving only Windows
Explorer open. Navigate to the
<CD-ROM Drive>:\LXI Drivers\EX Platform Requisites
directory
on the CD and run the
IVISharedComponents1.5.0.exe
program. Next, follow the on-screen
instructions. Do not proceed to the next step until this installation completes successfully. If
instructed to reboot the PC, it will be necessary to do so at that time.
Switch Instrument Driver Installation
If the VTEXSwitch instrument driver was installed previously on the host PC, proceed to
System/LXISync Instrument Driver Installation
. To install the VTEXSwitch instrument driver,
navigate to
<CD-ROM Drive>:\LXI Drivers\EX Switch Driver, IVI
on the CD and run the .msi
installer located in this directory.
System/LXISync Instrument Driver Installation
NOTE
Complete this step only if the LXISync capabilities of the EX1200A platform are required. Also,
if this driver was installed previously on the host PC, software installation is now complete.
To install the System/LXISync Instrument driver, navigate to
<CD-ROM Drive>:\LXI Drivers\EX
System Driver, IVI
on the CD and run the .msi installer located in this directory.
Please refer to
VTEX Switch Driver Programmer’s Manual
for programming guidelines.
Additional information about IVI drivers can be found on the web at
Information
about
the
LXI
standard
and
LXI
technology
can
be
found
at
N
ETWORK
C
ONFIGURATION
By default, the EX1200A will attempt to locate a DHCP server. If one is found, the IP address
assigned by the DHCP server will be assumed. Otherwise, after a timeout of 20 seconds, the unit
will attempt to obtain an IP address by using Auto IP.
Содержание Ametek EX1200A Series
Страница 17: ...VTI Instruments Corp 16 EX1200A Series Introduction EX1200A SERIES 1 U FULL RACK MAINFRAME DIMENSIONAL DIAGRAM ...
Страница 18: ...www vtiinstruments com EX1200A Series Introduction 17 EX1200A SERIES 3 U MAINFRAME DIMENSIONAL DIAGRAM ...
Страница 33: ......
Страница 51: ...VTI Instruments Corp 50 EX1200A Series Preparation for Use ...
Страница 64: ...www vtiinstruments com EX1200A Series Preparation for Use 63 ...
Страница 65: ......
Страница 73: ......
Страница 107: ...VTI Instruments Corp 106 EX1200A Triggering ...
Страница 109: ...VTI Instruments Corp 108 EX1200A Triggering FIGURE 6 1 EX1200A SERIES TRIGGER MODEL ...
Страница 143: ...VTI Instruments Corp 142 EX1200A Web Page Operation ...
Страница 145: ...VTI Instruments Corp 144 EX1200A Series Programming ...
Страница 155: ......
Страница 161: ......