EX1200A Series Preparation for Use
33
P
REPARATION FOR
U
SE
U
NPACKING
When an EX1200A system is unpacked from its shipping carton, the contents should include the
following items:
An EX1200A High-Density Switch/Measure and Control System Mainframe
Getting Started with LXI-based VTI Systems and Local Area Networks
application note
EX1200A
Series User’s Manual
(this manual)
VTEX Switch Driver Programmer’s Manual
(P/N: 82-0117-000)
VTEX Scanner Driver
Programmer’s Manual
(P/N: 82-0128-000)
VTEX System Driver Programmer’s Manual
(P/N: 82-0125-000)
VTI Instruments Corp. Drivers and Product Manuals
CD
Power line cord
All components should be immediately inspected for damage upon receipt of the unit.
D
ETERMINE
S
YSTEM
P
OWER
R
EQUIREMENTS
The power requirements of the EX1200A mainframes are provided in the
Specifications
section of
. As with any backplane-based system where modules share power, such as VXI and
PXI, the possibility exists where certain plug-in module combinations can draw too much power
from a power supply rail. As such, It is imperative that the chassis provide adequate power for the
modules installed. For more information on EX1200A mainframe power consumption, please
refer
. The user should confirm that the power budget for the system (for the chassis
and all modules installed therein) is not exceeded on any voltage line.
It should be noted that if the mainframe cannot provide adequate power to the module, the
instrument might not perform to specification and possibly damage the power supply. In addition,
if adequate cooling is not provided, the reliability of the instrument will be jeopardized and
permanent damage may occur. Damage found to have occurred due to inadequate cooling will
void the warranty on the instrument in question.
I
NSTALLATION
L
OCATION
EX1200As are designed to be largely insensitive to external electrical, magnetic, and thermal
disturbances. However, as with all precision instrumentation, certain precautions, if taken into
consideration, can help achieve maximum performance.
1)
The unit, particularly its front panel, should be located away from sources of high or low
temperatures. When used in a rackmount application with other heat-generating instruments,
EX1200As should be located as far away from the other instruments as possible, 1U
minimum. Multiple EX1200As, however, can be stacked directly on top of one another
without any performance degradation.
2)
Care should be taken to ensure that the fans at the rear and the air vents at the front of the
mainframe are not obstructed to allow for proper cooling.
Содержание Ametek EX1200A Series
Страница 17: ...VTI Instruments Corp 16 EX1200A Series Introduction EX1200A SERIES 1 U FULL RACK MAINFRAME DIMENSIONAL DIAGRAM ...
Страница 18: ...www vtiinstruments com EX1200A Series Introduction 17 EX1200A SERIES 3 U MAINFRAME DIMENSIONAL DIAGRAM ...
Страница 33: ......
Страница 51: ...VTI Instruments Corp 50 EX1200A Series Preparation for Use ...
Страница 64: ...www vtiinstruments com EX1200A Series Preparation for Use 63 ...
Страница 65: ......
Страница 73: ......
Страница 107: ...VTI Instruments Corp 106 EX1200A Triggering ...
Страница 109: ...VTI Instruments Corp 108 EX1200A Triggering FIGURE 6 1 EX1200A SERIES TRIGGER MODEL ...
Страница 143: ...VTI Instruments Corp 142 EX1200A Web Page Operation ...
Страница 145: ...VTI Instruments Corp 144 EX1200A Series Programming ...
Страница 155: ......
Страница 161: ......