13 - MAINTENANCE OF EQUIPMENT IN THE WINTER 

 

WARNING! 

 

 To make correct MAINTENANCE OF EQUIPMENT IN THE WINTER, contact your local 

representative. 

 

WARNING!

 

All electrical work must be performed by a qualified person in compliance with the enclosed 

instructions. 
If your filtration unit operated in a region where there is a risk of low temperatures, we recommend you 

to complete conservation for WINTERIZING (if the water freezes inside the filter, some parts of the 

filtration equipment can be damaged).  

 

For this purpose you should switch off the differential switch in the electrical control panel for the whole 
conservation period. Shut off the water supply line to the pool and make sure it does not contain water. 

Drain the water from the basin to a level of 1m from the top edge of the pool. 

In the technical compartment in the multiconductor connection box disconnect the electric motor wires.  

Unscrew the nut joining the pump and remove the pump from the technical part. Ensure that after 

draining the water from the pump, it was kept in a dry place. Turbine pump must be rotated manually 2-

3 times during the winter. 
Upon completion of the work do not forget to close the lid of filtration equipment and lock screws

.  

 

 
 

14 - Technical Support Center 

If you have questions or suggestions, or need additional technical information, please contact technical 

support at: 

 

                                                     e-mail: 

[email protected]

       

 

If you want to get information about other product of VSV Aqua Group, instructions for their use and 

installation, we invite you to visit us at INTERNET: 

www.vsv-group.com

.  

 

 

 
 

 

COPYRIGHT 

VSV Aqua Group reserves the right without notice to make changes to this manual, related to the 

improvement of equipment, and in case of inaccuracies and typographical errors. All these changes will 

be incorporated into new editions of this manual. You should visit our page on the Internet: 

www.vsv-

group.com

  to obtain updated information and new developments. 

VSV Aqua Group has full rights to patents, patent applications, trademarks, copyrights and other 

intellectual property associated with the content of this guide. This manual does not give you any license 

or other legal rights to the use of the above without the express written permission of VSV Aqua Group. 

 

 
 

 

 

 

 
 
 
 
CE declaration of conformity is issued in compliance with the 89/336/EEC rule of electromagnetic 
compatibility and with 73/23/EEC rule of safety requirements  for electric equipment. 

Содержание Aquatic U

Страница 1: ...INSTALLATION AND USER S GUIDE FILTRATION BLOCKS Aquatic U 15 m3 hour Equipment of high alloy steel for cleaning and filtering water in the pool...

Страница 2: ...www vsv group com 2...

Страница 3: ...14 Differential switch 14 Other security measures 14 5 ELECTRICAL CONNECTIONS 15 20 Electrical control panel 15 Wiring diagram of the electrical control panel 16 Connecting boxes 17 18 Electrical wir...

Страница 4: ...t a sufficient distance from parts made from stainless steel to avoid getting chemicals on stainless steel equipment Otherwise on the surface of stainless steel can form rust and turbidity 3 Spread th...

Страница 5: ...r standard filter membranes 6 15 microns front skimmer nozzle LED lights 2x10W 10000K the device of automatic water adding the suction pipe with pre filter grounding bolt Technical part includes one s...

Страница 6: ...hout heating BLOCK Aquatic U 15 m3 hour Total assigned power of 0 47 kW with spotlights 2 10W one speed pump 0 45kW 50Hz performance capacity 15 m3 hour height H max 13 5 m The technical part without...

Страница 7: ...for use with boilers Heat transfer 15 kW min 70 kW max BLOCK Aquatic U 15 m3 hour heat exchanger Total assigned power of 0 473 kW with spotlights 2 10W one speed pump 0 45kW 50Hz performance capacity...

Страница 8: ...unit capacity 9 kW BLOCK Aquatic U 15 m3 hour electric heater Total assigned power of 0 47kW with spotlights 2 10W 9 47kW with electric heater 9 kW one speed pump 0 45kW 50Hz performance capacity 15...

Страница 9: ...www vsv group com 9 2 DIMENSIONS OF EQUIPMENT...

Страница 10: ...the block on the wall of the pool as shown below taking care not to damage the waterproofing coating liner If necessary align it with the water level and fasten the block mounting bolts in a projecte...

Страница 11: ...by sand VENTILATION Warning Never cover the ventilation holes in the lid of the technical compartment Otherwise the equipment will have to work with increased productivity which increases power consu...

Страница 12: ...ble for water supply in your area Adding of water Bring the pipe to filtration unit and connect it to the inlet thread 3 8 inches provide a tight seal Filtration unit must be connected to the water su...

Страница 13: ...le copper cable 2 x 2 5 mm2 One end of the cable must be in the technical part near the transformer of spotlight Other end must be near the terminals in the filtering part With the help of terminals m...

Страница 14: ...cable is not protected you must install warning tape on top of the cable Under roads cables are laid at a depth of not less than one meter In all other cases the depth of the cable 0 6 m WARNING The t...

Страница 15: ...www vsv group com 15 5 ELECTRICAL CONNECTIONS Electrical control panel...

Страница 16: ...EL Connection of power supplies is made to the upper terminals of the differential switch observing polarity Power supply cable for pump and transformer of spotlight is connected to terminals accordin...

Страница 17: ...or pump and transformer of spotlight in the technical part through O ring Tighten the nut of seal to avoid getting water into the technical part Enter the cable into the connection box and connect the...

Страница 18: ...DIAGRAM of HEAT EXCHANGER Connect the filtration unit with electrical control panel according to this scheme electric control panel of filtration unit thermal protection switch switch heat exchanger...

Страница 19: ...artment of filtration unit heat exchanger pump electronic thermostat suction pipe discharge pipe expansion tank filtration unit electrical control panel electromagnetic valve non return valve boiler 3...

Страница 20: ...phase heater neutral phase ground neutral phase ground Electrical control panel neutral 3 phase ground neutral 3 phase ground main power supply main power supply to electric heater control box cable 2...

Страница 21: ...ible hose in the discharge nozzle Enough to keep the hose near the discharge nozzle Stop filling pipelines by water when the air bubbles will stop After filling the pipeline make sure that no leaks in...

Страница 22: ...ANING WARNING Replacing contaminated filter membranes can be performed only after turning off the filtration unit Switch off filtration equipment from power supply Remove the pre filter basket and rin...

Страница 23: ...r supply clean or replace the filter membrane After cleaning swimming pool again turn off filtration unit remove the cover from the basket replace the dirty membrane on clean Then turn on filtering 9...

Страница 24: ...ight and the size of the pool To measure the amount of chlorine you must use the test kits When pH adjusted Water volume Slow chlorination 40 m3 2 tablets 50 m3 2 tablets 60 m3 3 tablets 70 m3 3 table...

Страница 25: ...a filtration mode Triggering of safety fuse 6A in the electrical control panel Replace safety fuse 6A 3 Filtration unit spotlight does not shine filtration unit is working Triggering of protection fu...

Страница 26: ...during the winter Upon completion of the work do not forget to close the lid of filtration equipment and lock screws 14 Technical Support Center If you have questions or suggestions or need additiona...

Отзывы: