Appendix I:Manual/Automatic Turn Page 

Mode1----Manual Turn Page 

 

Press “Option” Button 

1)Display Battery Capacity rate 
2)

Display AC Voltage

 

3)Light over “AC-V” lighting 
4)Light over “Mode1” lighting 
Status display:Battery capacity(%),AC Voltage 

 

One Touch “Option” Button 
1)Display Battery Capacity rate 
2)

Display AC Output Power

 

3)Light over “AC-W” lighting 
4)Light over “Mode1” lighting 
Status display:Battery capacity(%),AC Output Power(Loads power) 

 

Содержание VST1000

Страница 1: ...ase Power Inverter Special Feature with LCD display Battery capacity rate Battery voltage AC voltage AC power Can be used to resistance inductive and capacitive load such as air conditioner fridge pum...

Страница 2: ...input 110V 120V 220V 230 240Vac output Pure sine wave output Frequency 50Hz 60Hz CE and RoHS Approved 24 months warranty ODM OEM available Before using the inverter you need to read and save the safet...

Страница 3: ...tery voltage AC voltage AC power Complete isolation type inverter technology Continuous operation at full power Wide DC input voltage range Wide working temperature range Low output harmonic distortio...

Страница 4: ...er Attentions Do not attempt to connect the any other power source including any AC power source Make sure the opening to the ventilation fan and vent holes are not blocked To avoid electrical hazard...

Страница 5: ...ries will damage it Do not attempt to repair the fault inverter yourself otherwise it may lead to a serious accident Please contact the manufacture s engineer 3 Functions This pure sine wave inverter...

Страница 6: ...6 Intelligent Cooling Fan DC Input Terminal 3 2 AC Output Panel Vent Outlet AC Output Receptacle LED Display On Off Switch...

Страница 7: ...7 Vent Outlet AC Output Receptacle LED Display Power On Off Mode1 Mode2 Shift PE GND Vent Outlet AC Output Receptacle LED Display Power On Off...

Страница 8: ...n Off Mode1 Mode2 Shift PE GND AC L AC PE GND Vent Outlet AC Output Receptacle Overload Protection LCD Display Power On Off Mode1 Mode2 Shift P S AC Output Receptacle For application demands of differ...

Страница 9: ...ntinuous wattage load of that appliance The startup load of an appliance is a major factor of whether this inverter can power it Startup load is momentary With many appliances it is approximately twic...

Страница 10: ...s the same as a single battery Parallel voltage stays the same as a single battery amperage increases Series Parallel both voltage and amperage increase 5 Protection Inverter is equipped with numerous...

Страница 11: ...input voltage has been reversed that has blown the fuses Correct the polarity of the input connections and replace the fuse If the unit does not work after replacing the fuse the unit has been permane...

Страница 12: ...er temperature I N P U T Bat Voltage Range 11V 15 5V 12V version 22V 31V 24V version 44V 62V 48V version Efficiency More than 90 Protection Battery Low Alarm Battery Low Shutdown Battery Polarity Reve...

Страница 13: ...rther improvement of products 8 Maintenance and Warranty The casing of the inverters may be cleaned regularly with a damp cloth not wet to prevent accumulation of dust and dirt The screws on the DC in...

Страница 14: ...2 Display AC Voltage 3 Light over AC V lighting 4 Light over Mode1 lighting Status display Battery capacity AC Voltage One Touch Option Button 1 Display Battery Capacity rate 2 Display AC Output Power...

Страница 15: ...etween 0 9xVnom and 1 29xVnom where Vnom is 12V 24V 48V depending on model and must be able to supply sufficient current to inverter The following table displays the recommended battery cable Fuse Bat...

Страница 16: ...lack 40A 12 480Ah 24V 10mm 2 Red 2 Black 20A 12 240Ah 48V 6mm 2 Red 2 Black 10A 12 120Ah 4000W 12V 25mm 2 Red 2 Black 40A 12 640Ah 24V 16mm 2 Red 2 Black 20A 12 320Ah 48V 10mm 2 Red 2 Black 10A 12 160...