background image

 

Pulse Generator Version: 1.0 

www.VSpeak-modell.de

 

Page 2/4 

1

 

Connection 

1.1

 

Input 

The pulse generator is plugged with its servo plug either at any receiver power slot, or at the 
PowerBox system at the slot designated P²-Bus, . . . or for programming: 

 

on a JetiBox or – 

 

using the JetiBox emulation of a Jeti DC / DS transmitter - with 
ext. marked slot of the Jeti receiver 

For the relevant servo channel, a 3-step switch can now be programmed in the transmitter with 
the values  -100% (OFF)    0% (PULSE)    +100% (ON). 

1.2

 

Output 

In principle, all devices that are otherwise directly plugged into a servo slot of the receiver can 
be connected to the output, the 3-pin post connector. 

Attention:

  The pin  has the same voltage as the input, ie. When the output is not 

connected, special care must be taken with regard to a short circuit. 

1.3

 

LED Indicator 

LED:  green (ON) 

→  servo output position ON 

 

green (flashing)  →  servo output in PULSE operation, with the LED ON time 

corresponding to the servo output ON duration 

 

red  (ON) 

→  servo output position OFF 

 

red (flashing) 

→  only if the JetiBox is plugged in to program the ON / OFF times: 

Display of the ON duration 

The  blue  LED  is  blinking  every  second  to  signal  the  normal  function  of  the 
Pulse Generator. 

 

 

blue LED 

LED green/red 

 

Servo output 

 

Содержание Pulse Generator

Страница 1: ...erate ON OFF pulses in the model Both the times for the ON and OFF duration can be set as well as the ON and OFF positions With a 3 step switch from the transmitter can then select the respective operating mode between OFF PULSE and ON One possible application would be e g the control of a smoke pump in flight would thus be smoke clouds of equal length and at equal intervals possible ...

Страница 2: ...ces that are otherwise directly plugged into a servo slot of the receiver can be connected to the output the 3 pin post connector Attention The pin marked has the same voltage as the input ie When the output is not connected special care must be taken with regard to a short circuit 1 3 LED Indicator LED green ON servo output position ON green flashing servo output in PULSE operation with the LED O...

Страница 3: ...he button or Value change with the buttons resp Example PowerBox With the PowerBox system the same settings as with the JetiBox are possible via the P Bus In addition you can also select the servo channel 1 26 with which the Pulse Generator is controlled and the setting of the priority for the status telemetry value It can be chosen between low high higher at highest where low is sufficient The st...

Страница 4: ...ies with the following European directives 2004 108 EC EMC Directive 2006 95 EC Low Voltage Directive LVD 2011 65 EC Restriction of Hazardous Substances RoHS The presumption of conformity is taken by applying the following harmonized standards EN60065 Audio video and similar electronic aparatus Safety requirements EN60332 Tests on electric and optical fibre cables under fire conditions EN60950 Inf...

Отзывы: