background image

INSTALLATION, OPERATION AND MAINTENANCE
VSI AWWA C508 RUBBER FLAPPER CHECK VALVE

© 2014 VSI Waterworks LLC

VRSG-3

02-16

5

Sec. 5.2 Installation

Valves in water-distribution lines shall, where practical, be located in easily accessible areas. 

 5.2.1

 During installation, there is the possibility of foreign materials inadvertently entering the valve. 

Foreign material can damage internal working parts during operation of the Check Valves. For this reason, 

Check Valves should be installed in the closed position with the embossed flow arrow on the valve body 

pointing in the direction of flow. Each valve should be placed on firm footing in the trench to prevent settling 

and excessive strain on the connection to the pipe. Piping systems should be supported and aligned to avoid 

damage to the valve. 

Sec. 5.3 Inspection

After installation and before pressurization of the valve, all pressure-containing bolting (top cover plate, seals, 

and end connections) should be inspected for adequate tightness to prevent leakage. In addition, an inspection 

should be made for adequate tightness of all tapped and plugged openings to the valve interior. Proper 

inspection at this time will minimize the possibility of leaks after pressurization of the piping system.

Sec. 5.4 Hydrostatic testing

To prevent time lost searching for leaks, it is recommended that valve excavations not be backfilled until after 

pressure tests have been made. After installation, it is desirable to hydrostatically test newly installed piping 

sections, including Valves, at some pressure above the system design pressure. The test pressure should not 

exceed the rated working pressure of the Valve. After the test, steps should be taken to relieve any trapped 

pressure in the body of the valve. The Rubber Flapper Swing Check Valve should not be operated in either the 

opening or closing direction at differential pressures above the rated working pressure. It should be noted that 

Valves seat better at or near the rated working pressure of the valve. It is also recognized that wear or foreign 

material may damage valve seating surfaces and may cause leakage (Ref. AWWA C600).

Sec. 5.5 Records

Upon completion of the installation, valve location, size, make, type, date of installation, number of turns to 

open, direction of opening, and other information deemed pertinent should be entered on permanent records.

Sec. 5.6 Application Hazards

Rubber Flapper Swing Check Valves should not be installed in applications or for service other than those rec-

ommended by the manufacturer. The following subsections for precautions are not all inclusive but will help 

avoid some application hazards. 

a. Rubber Flapper Swing Check Valves should not be installed in lines where service pressure will exceed 

the rated working pressure of the valve.

b. Rubber Flapper Swing Check Valves should not be used in applications that are exposed to freezing 

temperatures.

c. Thrust blocks, restrained joints, or other means of restraint are needed on or adjacent to valves on 

pipelines or where unusual conditions exist, such as high internal pressures, adjacent fittings, or 

unstable soils.

Содержание AWWA C508 Series

Страница 1: ...VSI Waterworks 2 48 AWWA C508 RUBBER FLAPPER CHECK VALVE Publication VRSG 3 FEB 2016 INSTALLATION OPERATION AND MAINTENANCE MANUAL VSI AWWA C508 RUBBER FLAPPER CHECK VALVE...

Страница 2: ...PER CHECK VALVE VRSG 3 02 16 2014 VSI Waterworks LLC 2 TABLE OF CONTENTS INSTRUCTIONS 3 SAFETY MESSAGES 3 GENERAL 4 UNLOADING 4 INSPECTION PRIOR TO INSTALLATION 4 STORAGE 4 INSTALLATION 4 INSPECTION A...

Страница 3: ...stantly alert to potential emissions of pipeline material and take appropriate safety precautions Always wear suitable protection when dealing with hazardous pipeline material also handle valves that...

Страница 4: ...recommendations is likely to result in damage to the valve SECTION 3 INSPECTION PRIOR TO INSTALLATION Rubber Flapper Swing Check Valves should be inspected at the time of receipt for damage in shipme...

Страница 5: ...hydrostatically test newly installed piping sections including Valves at some pressure above the system design pressure The test pressure should not exceed the rated working pressure of the Valve Afte...

Страница 6: ...e at all joints connections and areas of seals If leakage is observed all defective O rings seals gaskets or end connection sealing members should be replaced If the leakage cannot be corrected immedi...

Страница 7: ...ld be recorded SECTION 7 REPAIRS Leakage broken parts hard operation and other major defects should be corrected by a repair crew as soon as possible after the defect has been reported If repairs are...

Страница 8: ...n out debris Leakage between the body and cover of the valve Bolts and nuts may be loose or tightened irregularly Loosen then retighten bolts and nuts evenly Cover Gasket may be damaged Follow instruc...

Страница 9: ...isassembly and Reassembly 1 Shut off line flow fully 2 Screw backflush attachment fully inward by rotating in a clockwise direction to equalize pressure across valve 3 Loosen and remove the entire bac...

Отзывы: