Monitor Functions
The monitor function of the OS3.2 PC software allows to display some important data on the
PC screen with a continuous refresh cycle.
Select „Monitor“ from the „Tools“ menu to open the basic view of the monitor window. Click to
“Define” to open the definition window. You will find a list with all accessible parameters and
actual values, where however the texts may be unfounded.
With FU252, only the following register codes make sense:
C1 C2 Description
:
8
Actual conversion result in % of full-scale, format xxx.xxx % *)
:
9
Actual frequency on input A in Hz, resolution 0,1 Hz, format xxx xxx,x Hz
;
1
Actual frequency on input B in Hz, resolution 0,1 Hz, format xxx xxx,x Hz
;
3
Actual output voltage of the analogue output, scaling 0 – 10 000 millivolts